• Direct Vent Freestanding Stove • Natural Gas or Propane • Vent Horizontally or Vertically • Standard Residential • Mobile Home Approved Tested and Listed by Featuring the WARNING: - Omni-Test Laboratories, Inc. Portland, Oregon Report # 028–S–50c-5 ANSI Z21.88, Burner If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Introduction 2 Introduction We welcome you as a new owner of an Avalon Eden stove. In purchasing a Eden you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Eden is one of the finest home heaters the world over. This manual will explain the installation, operation, and maintenance of this stove.
Table of Contents Introduction 3 Operation Introduction & Important Information ................... 2 Before You Begin ................................................ 35 Location of Controls ............................................ 35 Safety Precautions Starting the Stove for the First Time ................... 36 Safety Precautions .............................................. 4 Turning the Stove On and Off ............................. 36 Features & Specifications Comfort Control ..........
Safety Precautions 4 • IF YOU SMELL GAS: * Do not light any appliance * Extinguish any open flame * Do not touch any electrical switch or plug or unplug anything * Open windows and vacate building * Call gas supplier from neighbor's house, if not reached, call fire department • • This unit must be installed by a qualified installer to prevent the possibility of an explosion. Your dealer will know the requirements in your area and can inform you of those people considered qualified.
Safety Precautions Do not place clothing or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it. • Light the heater using the built-in igniter. Do not use matches or any other external device to light your heater. The viewing glass should be opened only for lighting the pilot or conducting service.
Specifications 6 Features: - Installation Options: Ember Fyre™ Burner for "Wood Fire" Look Works During Power Outages (battery backup system) High Efficiency Optional Thermostat or Remote Control Optional Blower for Quicker Heat Distribution Convenient Operating Controls Variable-Rate Heat Output Accent Light - Freestanding Stove - Horizontal or Vertical Vent - Residential or Mobile Home - Straight or Corner Placement - Bedroom Approved Heating Specifications: Approximate Heating Capacity (in
Installation (for qualified installers only) 7 Installation Warnings: ! ! ! ! ! ! ! ! Failure to follow all of the requirements may result in property damage, bodily injury, or even death. This heater must be installed by a qualified installer who has gone through a training program for the installation of direct vent gas appliances. This appliance must be installed in accordance with all local codes, if any; if not, in U.S.A. follow ANSI Z223.1 and NFPA 54(88), in Canada follow B-149.
Installation (for qualified installers only) 8 Packing List Additional Items Required • • • • • • • • • Propane Conversion Kit Log Set Touch-Up Paint Batteries (4 AA and 1 9v) Rear Vent Flue Cover Intake Damper Plates (2) Exhaust Restrictor Extender Plate Vent (see “Venting Requirements” for details) Gas Line Equipment (shutoff valve, pipe, etc.
Installation (for qualified installers only) 9 Installation Hints: • Recommended Optional Equipment Installation Order: -- GreenSmart Remote -- Blower -- LP Conversion and other optional equipment • Install the logs last - they are fragile. • When determining the location of the stove, locate the wall studs (for horizontal penetrations) and ceiling trusses (for vertical penetrations). You may wish to adjust the stove position slightly to ensure the vent does not intersect with a framing member.
Installation (for qualified installers only) 10 Top to Rear Vent Modification NOTE: If using the rear vent configuration, make sure to review vent configuration before proceeding. Remove the cast iron stove top and flue cover to access the vent components (see page 29) NOTE: Use a magnetic-tipped nutdriver on these screws - take care to prevent the screws from falling into the intake channel. Remove the outer flue assembly, cover plate, and gaskets.
Installation (for qualified installers only) 11 Top to Rear Vent Modification (continued) Install the inner flue assembly and exhaust cover plate. Make sure the attached gaskets are in place and form an air-tight seal. NOTE: Install the flue assembly with the diffuser to the bottom. Install the outer flue assembly, cover plate, and gaskets. Make sure the gaskets are correctly positioned and form an airtight seal. The flue cover with a cutout may be discarded.
Installation (for qualified installers only) 12 Heater Placement Requirements • Heater must be installed on a level surface capable of supporting the heater and vent • Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies.
Installation (for qualified installers only) 13 Optional Wall Switch or Thermostat Installation Do not connect 110-120 VAC to the gas control valve or wiring system of this stove. The switch must be installed by a qualified installer. This stove may be installed with an optional wall switch or thermostat. wires will interrupt the burner circuit (see item “a” below). The thermostat (or on/off switch) 1.
Installation (for qualified installers only) 14 Gas Line Installation ! The gas line must be installed in accordance with all local codes, if any; if not, follow current ANSI Z223.1 or NFPA 54 in the USA and the current CGA B149 in Canada. ! The heater and gas control valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPA). For pressures under 1/2 psig (3.
Installation (for qualified installers only) 15 Vent Requirements • The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use its own separate vent system. • In addition to the requirements listed here, follow the requirements provided with the vent. • When the vent passes through a wall a wall thimble is required.
Installation (for qualified installers only) 16 Approved Vent Configurations Overview This appliance has several components used to control the flow of intake air and exhaust gases. Depending upon vent configuration, you may be required to adjust the intake restrictor, exhaust restrictor, diffuser and/or install the intake dampers and extender plate. Refer to the vent configuration (pages 18 to 23) to determine the correct restrictor, damper, extender, and diffuser settings.
Installation (for qualified installers only) 17 Exhaust Restrictor NOTE: Refer to the vent configuration (pages 18 to 23) to determine the correct restrictor position. Firebo Back W all of F x Roo f Loosen these two screws irebox on the exhaust restrictor. Slide the restrictor to the correct restrictor position (see the illustration below). The screw location indicates restrictor position. In this example, the restrictor is set in position # 3. Tighten the screws to secure the restrictor.
Installation (for qualified installers only) 18 Rear Vent Configurations with Horizontal Termination and No Rise • Use 8” Diameter Vent with a 6-5/8” to 8” adapter (increaser). We recommend using the minimum vent kit from Travis Industries (SKU 96200311). This kit contains the following components used to vent the stove through a typical exterior wall: -- 6-5/8” to 8” Adapter (Black) -- Thimble -- Thimble Cover (Black) -- Pipe (3.
Installation (for qualified installers only) 19 Rear Vent Configurations with Horizontal Termination and 1’ Min. Rise • Maximum of one (1) 45° or 90° horizontal elbow may be used (see illustration). • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly, especially when the termination is near a demarcation line.
Installation (for qualified installers only) 20 Rear Vent Configurations with Vertical Termination • Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel. • A maximum of three (3) elbows may be used (e.g.: one 90° and two 45° or three 90°). • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. NOTE: Restrictor positions are based upon lab tests.
Installation (for qualified installers only) 21 Rear Vent Configuration Vented into Fireplace with Co-Linear Adapter • Attach the Co-Linear adapter directly to the back of the stove. Use two (2) 3” flex vents to vent the appliance through a code-conforming masonry or metal (zc) fireplace. All clearances to combustibles must be met and the flex vent must be vented through a non-combustible fireplace chimney. • Use a high-wind termination cap. • Vent height must be a minimum 10’ and maximum 25’.
Installation (for qualified installers only) 22 Top Vent Configuration with Vertical Termination A maximum of four (4) 45° or 90° elbows may be used. Of these elbows, only one (1) may be a horizontal elbow (see illustration). • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly, especially when the termination is near a demarcation line.
Installation (for qualified installers only) 23 Top Vent Configuration with Horizontal Termination A maximum of four (4) 45° or 90° elbows may be used. Of these elbows, only one (1) may be a horizontal elbow (see illustration). • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly, especially when the termination is near a demarcation line.
Installation (for qualified installers only) 24 Vent Termination Requirements (see illustration below) ! Venting terminals shall not be recessed into a wall or siding. A Minimum 9" (229mm) clearance from any door or window B Minimum 12" (305mm) above any grade, veranda, porch, deck or balcony C Minimum 12" (25mm) from outside corner walls NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. Roof Surface Roof Eaves 11" Min. (279mm) 6" Min.
Installation (for qualified installers only) 25 Class A Chimney Conversion Kit (top vent configuration only) Simpson Duravent provides a conversion kit for those wishing to use an existing wood stove chimney to vent this direct vent stove. The illustration below gives an overview of this type of installation. See the instructions included with the kit for details. ! Do not exceed the maximum vertical rise (see the section "Approved Vent Configurations" starting on page 16) allowable.
Installation (for qualified installers only) 26 Interior Masonry Chimney Conversions (top vent configuration only) • Follow the requirements and use the equipment listed in the illustration below to install this appliance into an interior masonry chimney. • Maximum vertical rise is 40' • Minimum vertical rise is 10' • See the chart on page22 for determining the correct restrictor position. NOTE: these restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly.
Installation (for qualified installers only) 27 Steps for Finalizing the Installation 1. Remove the glass (see page 29). NOTE: 2. 3. 4. If using propane (LP) convert the appliance prior to installing the logs. We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected once it enters the firebox, ensuring gas does not build up. Make sure the accent light bulb is in place.
Installation (for qualified installers only) 28 5. 6. 7. 8. 9. Install the logs (see page 31). Replace the glass. Start the heater. Leak test all gas joints. Check the air shutter following the directions below. Air Shutter Adjustment Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.
Finalizing the Installation (for qualified installers only) 29 Face and Glass Removal ! Make sure the gas control valve is “OFF” and the heater is cool prior to conducting service. c a Open the two latches holding the glass frame in place - follow the directions shown below Lift the stove flue cover and stove top off the stove and place it aside. Top of Firebox Latch Glass b Remove the stove front by lifting it up then forward. Place it aside.
Finalizing the Installation (for qualified installers only) Glass Frame Removal and Installation (continued) The latch can come loose from glass frame anchor. This occurs when it is turned 1/4 turn when it is disengaged. Follow the directions below to re-install the latch if it becomes loose. Hold the latch at an angle and insert it into the slot on the glass frame anchor. Latch NOTE: this slot may be at a different angle than illustrated.
Finalizing the Installation (for qualified installers only) 31 Log Installation ! The logs are fragile, especially after being exposed to heat. • Make sure the gas control valve is “OFF” and the heater is cool prior to conducting service. • Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
Finalizing the Installation (for qualified installers only) Left Log Placement The left log has one hole and one elevated pad on the bottom. Place the log so the pin on the burner inserts into the holes on the log and the pad inserts over the screw on the burner (see photos below). Right Log Placement The right log has two holes on the bottom. Place the log so the two pins on the burner insert into the holes on the log (see photos below).
Finalizing the Installation (for qualified installers only) 33 Left Twig Placement The left twig is the shorter twig(see photo below). The bottom of the twig has two holes. Place the twig so the pins on the rear and left log insert into the holes on the twig. Left Twig Right Twig Right Twig Placement The right twig has two holes in the bottom that fit over the pin on the back and right log (see photos below). The lower side of the twig rests on the right log. Place the twig as shown below.
Finalizing the Installation (for qualified installers only) Ember Placement Place a layer of embers along the edges of the burner to achieve an aesthetic appearance. Also place an ember over the screw on the right side of the burner (see photos below). Rockwool Installation The included rock wool is placed on top of the burner to enhance the glow from the burner. The rock wool works best when it is applied in a very thin, porous layer.
Operation 35 Before You Begin Warning: Read this entire manual before you use your new stove (especially the section "Safety Precautions" on pages 4 & 5). Failure to follow the instructions may result in property damage, bodily injury, or even death. Warning: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.
Operation 36 Starting the Stove for the First Time • Burn the heater at a high setting with the blower off for an extended period (up to 48 hours). This will cure the painted surfaces. Fumes from the paint curing and oil burning off the steel will occur. This is normal. We recommend opening a window to vent the room. • Condensation may appear on the glass each time you start the stove - this is normal. • Blue Flames will occur on the stove when it first comes on.
Operation 37 Accent Light HIGH OFF This stove has a built-in accent light that may be turned on and off and dimmed to your preference. Turn the knob to achieve the desired light output. LOW ACCENT LIGHT OFF LOW HIGH Adjusting the Optional Blower Speed The blower helps transfer heat from the heater into the room. It will not turn on until the heater is up to temperature (approximately 15 minutes after starting). See the illustration below for instructions on adjusting the blower speed.
Operation 38 Normal Operating Sounds Extinction Pops It is not unusual, especially on Propane (LP) appliances, to experience a "pop" when the burner is shut off. The appliance may creak with change of temperature -- THIS IS NORMAL. Blower This heater has an optional blower to push heated air into the room. You will hear the sound of air movement that increases as the speed is increased. Pilot Assembly The pilot flame will make a clicking sound when starting up.
Maintenance (for qualified service personnel only) 39 Maintaining Your Stove's Appearance Painted Surfaces • Painted surfaces should be cleaned with a duster. If scratches occur, lightly sand the area with fine sandpaper. Clean the area and, with the stove cool, apply one or two thin coats of stove paint to the area (mask the area to avoid overspray). Allow the stove to dry, then turn the stove on to cure the paint (1 hour on medium).
Maintenance 40 (for qualified service personnel only) Accent Light Replacement An accent light is included in your stove to provide additional lighting. This bulb will burn out over time. To replace, follow the directions below: • • • Shut off gas to the stove and let it cool for 15 minutes. Remove the glass (see page 29) and logs (see page 31). Replace the halogen bulb with the following bulb: (NOTE: .
Maintenance (for qualified service personnel only) 41 Troubleshooting Table Problem: Main Burners Will Not Start Receiver Beeps Thermostat Does Possible Cause: Don't Call for Service Until You: The ON/OFF switch is turned to "OFF" Turn the ON/OFF switch to "ON" The remote control is not working correctly See the remote control instructions The thermostat is disconnected or set too low See "Thermostat Operation" No Propane in Tank Check Tank Level The power backup batteries are dead Replace th
Maintenance 42 (for qualified service personnel only) Wiring Diagram Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Safety Label 43 Safety Label The safety (listing) label is on the back of the stove. A copy is shown below. Tested & Listed By Eden Portland Oregon USA Vented Gas Fireplace Heater REPORT #028-S-50c-5 Certified for USA and Canada Tested to: ANSI Z21.88-2009/CSA 2.33-2009 “Vented Gas Fireplace Heater”, CGA 2.17-M91, UL 307b-1995 “Gas Burning Heating Appliances for Manufactured Homes”, and CSA P.4.1-09 Tested method for measuring annual fireplace efficiency.
Limited 7 Year Warranty 44 Register your TRAVIS INDUSTRIES, INC. Limited 7 Year Warranty online at traviswarranty.com, or complete the enclosed Warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas appliance (appliance is defined as the equipment manufactured by Travis Industries, Inc.
Optional Equipment (for qualified installers only) 45 LP Conversion Instructions Install the conversion kit prior to installing the gas line to ensure proper gas use. 1 Remove the glass (see page 29). Remove the logs and embers (if installed - page 31). 2 Remove the burner (see below). Grasp the burner with both hands and lift it straight up and out of the firebox.
Optional Equipment (for qualified installers only) 3 Follow the directions below to replace the orifices. 1/2" Wrench b Apply thread sealant to the LP orifices prior to installation. Use the chart below to identify the correct orifices. Rear Burner Orifice Front Burner Orifice a Use a 1/2" open end wrench to unscrew the two orifices. Look here for the orifice identification c Screw each LP orifice in so the orifice protrudes 15/16" (24mm) (indicating full insertion).
Optional Equipment 4 a (for qualified installers only) 47 Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice Lift the pilot hood c off the pilot Remove the orifice and replace with the LP orifice. Screw the orifice all the way in and replace the pilot hood. assembly. Orifice Identification: LP (Propane) Orifice b 35 Use a hex wrench to 35 unscrew the orifice.
Optional Equipment 48 (for qualified installers only) GreenSmart™ Remote Control Installation Packing List • • • • • • • • • • • • • • Transmitter Receiver (with Cover Plate & Switch) Fan Control Module Velcro LP or NG Stepper Motor (with screws and label - attaches to Valve) Wire Harness (2) Power Leads (4) AA Batteries (inside receiver box) (2) #8 x ½” Machine Screws (2) Wire Ties Torx T-20 Wrench Wall Mount (for placing the transmitter on a wall) (2) Drywall anchors (for wall mount) (2) #8 x 3/8” Typ
Optional Equipment 49 (for qualified installers only) Overview The GreenSmart remote includes a new wiring harness that replaces the stock wiring harness. Before installing, familiarize yourself with the stock and updated wiring diagrams (see the illustrations on this page and and following page).
Optional Equipment (for qualified installers only) GreenSmart Wiring Diagram CN4 Comfort Control Valve Spark Rod Pilot Sensor PILOT SENSOR DIGITAL FIREPLACE CN0 BURNER SPARK ROD Pilot Ground CONTROL VALVE DIAGNOSTIC COMMAND GROUND CN3 STEPPER MOTOR POWER CN1 CN2 BURNER CONTROL RECEIVER Orange VALVE Green Yellow / Green Remote Receiver IPI / CPI Blue White TOP 50 CONTINUOUS PILOT (4) AA Batteries FAN CONTROL Fan Controller POWER INTERMITTENT PILOT 110V OUT FAN AUX OUT 120
Optional Equipment 51 (for qualified installers only) Installation 1 WARNING: Make sure power to the stove has been shut off prior to installation. NOTE: Refer to the wiring diagram on page 50 while making wiring harness connections. Loosen the bottom panel attachment screws (there are two on each side see Figure 1). Slide the bottom panel back and place it below the stove (see Figure 2). This allows for access to the controls under the stove.
Optional Equipment 52 3 (for qualified installers only) Unplug the ac adapter from the power harness (see Figure 5). You can leave the ac adapter plugged into the wiring harness. Figure 5 4 Disconnect the molex connector leading to the gas control valve (see Figure 6). WARNING: The tabs on the gas control valve are fragile. Take care when removing the molex connector to not pull or damage the wires or tabs.
Optional Equipment 6 Disconnect the comfort control valve connection (see Figure 8). Disconnect the burner control connector from the fireplace burner control (see Figure 9). Figure 8 7 53 (for qualified installers only) Figure 9 Disconnect the on/off switch wires (labeled ON/OFF - see Figure 10). Unscrew the on/off/battery plate from the control panel (see Figure 11). Figure 10 Figure 11 8 Pull the plate and wiring forward (see Figure 12).
Optional Equipment 54 9 (for qualified installers only) Use the included torx wrench to remove the stock regulator (see Figure 14). The old regulator may be discarded. Figure 14 10 The stepper motor (adjustable regulator) has an installation sheet included with it – make sure to follow all of the directions. Place the stepper motor on the gas control valve (see Figure 15) – MAKE SURE IT IS CORRECTLY ORIENTED. Secure using the screws included with the motor (see Figure 16) – tighten to 25 Lb-inches.
Optional Equipment 55 (for qualified installers only) 12 Attach the wiring harness to the burner control (see Figure 18). Attach the gas control valve molex connector (see Figure 19). Figure 18 Figure 19 13 Attach the blue and white wires to the IPI/CPI switch (see Figure 20). Connect the wiring harness to the stepper motor (see Figure 21). Figure 20 Figure 21 14 Attach the wiring harness to the comfort control valve connection (see Figure 22).
Optional Equipment (for qualified installers only) 15 Place the fan controller on the bottom panel as shown in Figure 23. Make sure the control module is positioned with the power cord to the right and the module at the back edge of the bottom panel. Figure 23 16 Attach the power cord from the fan controller to the AC connection (see Figure 24). Attach the connector labeled “FAN CONTROL” on the wiring harness to the fan control module (see Figure 25).
Optional Equipment (for qualified installers only) 57 18 Attach the accent light power lead to the fan controller in the “AUX OUT” receptacle (see Figure 28). Figure 28 NOTE: If using the optional fan, you will want to disconnect its power lead and connect it to the extra power lead included with this kit, then connect it to the “FAN” receptacle on the fan controller. See the blower installation instructions for details.
Optional Equipment (for qualified installers only) 20 Attach the receiver to the control panel with the two #8 machine screws (Figure 31). Figure 31 21 Re-attach the bottom plate to stove, taking care to prevent any wiring from being pinched (see Figure 32). Use the included wire ties, if necessary, to keep all wiring from contacting any hot or moving components. Figure 32 22 Place batteries into the receiver and transmitter (see Figure 33).
Optional Equipment (for qualified installers only) 59 23 Place the receiver coverplate (and switch) over the receiver (see Figure 35) and attach with the two screws included with the receiver (see Figure 36) Figure 35 Figure 36 24 A wall mount is included with this kit for the remote. It may be mounted to the wall for easy access and storage. Use the included drywall anchors (and screws) to secure it to the wall (see Figure 37).
Index 60 Approved Vent Configurations ............................. 16 Adjusting the Blower Speed ................................. 37 Adjusting the Flame Height .................................. 36 Air Shutter Adjustment ......................................... 28 Altitude Considerations ........................................ 15 Blower Control...................................................... 37 BTU Input ............................................................. 6 BTU Output .................