Owner`s manual
32 Listing Label 
© Travis Industries  100-01252_000  4101004 
Listing Label 
HOT WHILE IN OPERATION. DO NOT TOUCH. CONTACT MAY CAUSE SKIN BURNS. 
KEEP FURNISHINGS AND COMBUSTIBLE MATERIAL A CONSIDERABLE DISTANCE 
AWAY. SEE NAMEPLATE AND INSTRUCTIONS. DO NOT OVERFIRE. IF HEATER OR CHIMNEY CONNECTOR 
GLOWS, YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. 
UNDER CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO NOT USE GRATE 
OR ELEVATE FIRE. BUILD FIRE DIRECTLY ON HEARTH. OPERATE ONLY WITH FIREBRICK IN PLACE. 
OPERATE ONLY WITH DOOR CLOSED. OPEN FEED DOORS TO FEED FIRE ONLY. USE OF OTHER FUELS 
MAY DAMAGE THE HEATER AND CREATE A HAZARDOUS CONDITION.
TYPE OF FUEL: SOLID WOOD ONLY.
DO NOT REMOVE THIS LABEL
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSTALLATION AND RESTRICTIONS IN YOUR AREA.
SUITABLE FOR USE IN CONVENTIONAL RESIDENTIAL INSTALLATIONS, MANUFACTURED HOMES AND ALCOVES.
Report No. 100217684PRT-001
Control No. 4000515
MODEL:
CAMANO
Certified for USA and Canada
SERIAL NO:
CM
Tested to: UL 1482 and ULC S627-00
PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer’s installation and operating instructions. Contact your local building or fire officials 
about restrictions and installation inspection in your area. Refer to local building codes and manufacturer’s instructions for precautions required for passing a 
chimney through a combustible wall or ceiling. Do not run a chimney connector through a combustible wall or ceiling. Do not connect this unit to a chimney flue 
serving another appliance. Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building 
or fire officials.
FREESTANDING INSTALLATION
STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6” diameter, minimum 24 MSG black, with listed UL-103 HT factory-built chimney, suitable for 
use with solid fuels or masonry chimney. Pedestal or legs are required.
ALCOVE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. Pedestal or legs are required.
MANUFACTURED HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. In addition, manufactured 
home installations require outside air - use the optional pedestal or outside air boot.
AMERI-TEC model DCC connector with model HS chimney
DURA-VENT model DVL connector with DURA-PLUS chimney
GSW-JAKES EVANS SUPERPIPE 2100
I.C.C. EXCEL (103-HT) chimney with HP connector
METALFAB model DW connector with TG chimney
OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
SELKIRK METALBESTOS model DS connector with model SSII chimney
Singlewall Connector
Conventional Residential
Installations
Manufactured Home, Alcove and Reduced
Clearance Installations
(Requires Doublewall Connector)
A. Sidewall to Unit
B. Backwall to Unit
C. Cornerwall to Unit
D. Sidewall to Connector
E. Backwall to Connector
F. Cornerwall to Connector
G. Side & Rear Floor Protection
H. Front Floor Protection 
18 in. (458 mm)
16.5 in. (420 mm)
10 in. (254 mm)
27 in. (686 mm)
19.5 in. (496 mm)
19.5 in. (496 mm)
US: 6 in. (153 mm) / CAN: 8 in. (204 mm)
US: 16 in. (407 mm) / CAN: 18 in. (458 mm)
13 in. (331 mm)
9 in. (229 mm)
7.5 in. (191 mm)
21.5 in. (547 mm)
11.5 in. (293 mm)
16.5 in. (420 mm)
US: 6 in. (153 mm) / CAN: 8 in. (204 mm)
US: 16 in. (407 mm) / CAN: 18 in. (458 mm)
FREESTANDING CLEARANCE DIAGRAM ALCOVE SPECIFICATIONS FLOOR PROTECTION DIAGRAM
STOVE
D
A
EB
STOVE
45˚
F
C
SIDEWALL
BACKWALL
ADJACENT WALL
ADJACENT WALL
G
STOVE
G G
H
FRONT
FLOOR PROTECTOR
Floor protection must be a non-combustible
material extending beneath the heater and to
the front, sides and back as indicated. See
Owner’s Manual for examples of non-com-
bustible materials that can be used.
Do not obstruct space beneath heater.
Max. Alcove Depth:
Min. Alcove Height:
Min. Alcove Width:
48 in. (1220 mm)
See Owner’s Manual
See Owner’s Manual
Electrical Rating:
Optional Blower:
115V., 60 Hz, 1.8 Amps
# 99000138 
Replace glass only with 5mm neoceramic or
ceramic glass.
Do not route power cord under or in front of appliance.
TRAVIS INDUSTRIES, INC.
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
Manufactured by:
www.travisproducts.com
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with July 1990 particulate emission standards.
Made in U.S.A.