16 Stove Installation (for qualified installers only) 
© Travis Industries  100-01252_000  4101004 
Exterior Factory 
Built Chimney 
Chimney Cap
(See the section "Chimney 
Termination Requirements" 
for more details)
Chimney Sections
Minimum Air Space to 
Combustibles (See 
Chimney Manufacturer's 
Instructions)
Chimney Connector 
Sections
Follow the chimney 
manufacturer's 
instructions and 
clearances for roof 
penetrations. A storm 
collar and flashing are 
required (some 
require a radiation 
shield).
}
Stove Clearances
(See the section "Stove 
Placement Requirements" 
for more details)
}
Follow the chimney 
manufacturer's 
instructions and 
clearances for wall 
penetrations. A 
wall radiation shield 
(thimble) is 
required.
Optional 
insulated 
chase
Wall Bands 
and 
Supports
Insulated Tee
(with cleanout )
Min. 18" 
(457mm) 
clearance to 
ceiling
Floor Protection
(See "Floor 
Protection 
Requirements" 
for details)
Minimum 15' (4.57M) 
Maximum 33' (10.05M)
Figure 12
Hearth Stove 
Positive 
Connection 
Remove damper 
or wire it open
Airtight Insulated 
Clean-Out
Min. 18" 
(457mm) 
Combustible 
Mantle
NOTE: The entire fireplace and 
chimney must be clean, undamaged, 
and meet all local building codes 
(UBC, etc.). Damage must be 
repaired prior to installation. The 
chimney must be 15' (4.57M) to 33' 
(10.05M) tall.
Floor Protection
(See the section 
"Floor Protection 
Requirements" 
for more details)
See the section 
"Stove Placement 
Requirements" for 
minimum clearances 
required.
The liner must be 
stainless steel connector 
or flexible vent. Follow 
the liner manufacturer's 
instructions for installation 
and support.
Cap and flashing 
prevents water from 
entering
Figure 13