Horizontal Terminations
5. Use a single 90°
elbow (NOTE:
an additional 45°
elbow may be
used on the
horizontal run).
6. If using 6-5/8"
diameter vent, a
minimum 12"
vertical section is
required.
7. The termination
must fall within
the shaded area
shown in the
chart. Use the
indicated
restrictor
position.
5 feet
10 feet
0 feet
0 feet
5 feet
5 feet
0 feet
0 feet
10 feet
5 feet
10 feet
14'
(max)
10 feet
Restrictor
Position # 1
14 feet
(max)
14 feet
(max)
14 feet
(max)
NOTE:
If using 6-5/8" diameter vent, a minimum 12" vertical section is required.
NOTE:
Horizontal sections require a 1/4" rise every 12" of travel.
NOTE:
Restrictor positions are based upon lab tests. The ideal restrictor position