38 Listing Label
© Travis Industries 100-01190_003 4100818
Listing Label
TYPE OF FUEL: SOLID WOOD ONLY.
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. DO NOT
OVERFIRE. IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND
CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO NOT
USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE ONLY WITH FIREBRICK IN PLACE.
OPERATE ONLY WITH DOOR CLOSED. OPEN FEED DOORS TO FEED FIRE ONLY. USE OF OTHER FUELS MAY DAMAGE THE
HEATER AND CREATE A HAZARDOUS CONDITION.
Report No. 028-S-75-2
Tested to: UL-1482
Portland
Oregon USA
Tested &
Listed By
Model: LEYDEN - ARBOR
DO NOT REMOVE THIS LABEL
Listed Solid Fuel Burning Appliance.
Serial Number
Suitable for use in conventional residential installations, mobile homes and alcoves.
www.travisproducts.com
PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer’s installation and operating instructions. Contact your local building or fire officials about restrictions and
installation inspections in your area. Refer to local building codes and manufacturer’s instructions for precautions required for passing a chimney or chimney connector through a combustible
ceiling. Do not connect this unit to a chimney flue serving another appliance. Use a minimum 24 MSG black or 26 blued steel chimney connector, connected to a lined masonry chimney, or UL
103HT factory-built chimney suitable for use with solid fuels. Minimum clearance between horizontal chimney connector and combustible materials - 18 in. Clearances may be reduced by
methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building or fire officials.
WARNING - MOBILE HOME - An outside air inlet must be provided for combustion air, and be unobstructed while in use. Do not install appliance in a sleeping room. The structural integrity of
the mobile home floor, walls and ceiling/roof must be maintained.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route power cord away from unit. Do not route power cord over or under appliance.
Minimum Clearances to Combustible Materials - Freestanding Installation
Singlewall Connector
Conventional Residential
Installations
Reduced Clearance
Conventional Residential
Installations
Singlewall Connector
with Pipe Shield
Conventional Residential
Mobile Home
Installations
Alcove
Installations
A.
B.
C.
D.
E.
F.
Sidewall to Unit
Backwall to Unit
Corner to Unit
Sidewall to Connector
Backwall to Connector
Corner to Connector
18.00 in.
27.25 in.
19.00 in.
28.75 in.
21.00 in.
23.00 in.
18.00 in.
20.75 in.
14.00 in.
28.25 in.
14.00 in.
17.50 in.
18.00 in.
17.25 in.
14.00 in.
28.75 in.
11.00 in.
18.00 in.
18.00 in.
20.75 in.
14.00 in.
28.25 in.
14.00 in.
17.50 in.
18.00 in.
20.75 in.
N/A
28.25 in.
14.00 in.
N/A
Freestanding Clearance Diagram
STOVE
D
A
EB
STOVE
45˚
F
C
SIDEWALL
BACKWALL
ADJACENT WALL
ADJACENT WALL
Floor Protection Diagram
6
STOVE
6 6
16 FRONT
FLOOR PROTECTOR
Floor protection must be a non-combustible
material extending beneath the heater and to
the front, sides and back as indicated. See
Owner’s Manual for examples of non-com-
bustible materials that can be used.
Alcove Specifications:
Maximum 48 inch depth,
minimum 84 inch height,
minimum 63.25 inch width.
COMPONENTS REQUIRED FOR MOBILE HOME, ALCOVE,
AND REDUCED CLEARANCE CONVENTIONAL RESIDENTIAL
INSTALLATIONS.
One of the following listed chimney connectors and
compatible chimney systems:
AMERI-TEC model DCC connector with model HS chimney
DURA-VENT model DVL connector with DURA-PLUS
chimney
GSW-JAKES EVANS SUPERPIPE 2100
I.C.C. EXCEL (103-HT) chimney with HP connector
METALFAB model DW connector with TG chimney
OLIVER MACLEOD PROVENT model PV connector with
model 3103 chimney
SECURITY model DP connector with SECURITY model
ASHT or S2100 chimney
SELKIRK METALBESTOS model DS connector with model
SSII chimney
OPTIONS: 125 CFM Blower Package (Rated 120v, 1.8 Amp, 60hz)
Notes: Replace glass with 5mm neoceramic or ceramic glass only.
For use with solid wood fuels only. Operate only with feed door closed - open to feed fire only.
Do not use a grate or elevate fire - build fire directly on the hearth.
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with July 1990
particulate emission standards.
Manufactured by: Travis Industries, Inc.
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275