User guide
AVALON RF, INC.    Page 4 of 28 
DX404/DX504/DX604 User’s Guide & Operating Manual 
2.  Specifications 
2.1  Power Input (Circle 9 on rear panel). 
a) The power input connector is a XLR 4 pin on the rear panel of the 
DX604. 
Pin 1 – Ground 
Pin 2 – RS232 Interface (Transmit) 
Pin 3 – RS232 Interface (Receive) 
Pin 4 - +9Vdc to +16Vdc 
             Figure C – Power Input 
b) The DX604 operates off a 9Vdc to 16Vdc unregulated voltage 
source with a ripple of less than 0.5Vp.p. 
c)  Input Current is under 1 Amp at an input voltage of 12Vdc. 
d) Power is switched via an ON/OFF mechanical switch. 
e) The DX604 power input is protected against over voltage and 
reverse polarity. 
A bi-color LED on the rear panel indicates the condition. Yellow 
indicates over voltage and Red indicates reverse polarity. 
NOTE 
f)  The RS232 interface option on pins 2 and 3 is used to remotely 
program and setup the DX604 as described in Appendix B. 