Owner's Manual
10
Clearance Requirements
When installing the ice maker under a counter, follow the recommended spacing dimensions shown.
To ensure proper service access and venlaon, allow at least 2” of clearance at the back, 1/4” at the top, and
1/4” at the sides. The installaon should allow the unit to be pulled forward for servicing, if necessary.
Note: The ice maker should be installed on a rm and level surface that will be able to support the
enre weight of the unit. It is important for the ice maker to be level in order to work properly. If
needed, you can adjust the height of the ice maker by rotang the feet. See the “Leveling the Ice
Maker” secon.
Note: A standard electrical supply (115 VAC only, 60 Hz), properly grounded in accordance with
Naonal Electrical Code and local codes and ordinances, is required.
Notes:
• To ensure proper service access and venlaon, at least 2 inches of clearance at the back as
shown in the diagram.
• The installaon should allow the unit to be pulled forward for servicing, if necessary.
• A standard electrical supply (115 VAC only, 60 Hz), properly grounded in accordance with
Naonal Electrical Code and local codes and ordinances, is required.
Top ViewSide View
2”
”
90
1
”
14
”
”
”
2”
1
”
1
”
W
A
L
L
Door Swing