User`s manual
Table Of Contents

AuviTran Network ASIO Streamer 7
3.2.2 Deactivating the ASIO streaming mode
Follow the reverse path to disable ASIO streaming and return the port to its original configuration.
1. In the port‟s control tab, disable the ASIO streaming mode and enable 3
rd
port access.
2. Disconnect the port from the control PC or the Ethernet switch.
3. Associate the port with the port A.
3.2.3 Routing of the ASIO streams
The AVM500-ES gives access to 64 ASIO inputs and 64 ASIO outputs per capable port. In the example patch below, the
ASIO feature is enabled on Port-E and the 64 ASIO outputs are routed from the port-E to the port-B and from there 2
channels are patched to an AuviTran AVA4-ES100:
3.3 Configuration of an AV3rd-ES100
There is nothing to configure here, the ASIO streaming is always active.
3.3.1 Routing the ASIO streams
The 64 ASIO output channels are connected to the SRC1-SRC64 EtherSound channels. The 64 ASIO input channels are
connected to the DST1-DST64 EtherSound channels. In the example patch below, the first two ASIO output channels are
sent to an AVA4-ES100: