User`s manual

AVY16-ES100 User’s Manual AuviTran
14
14.2.6.2 “Redundant OUT” configuration
This mode indicates that AVY16-ES100 behaves as AVRed-ES100 “OUT”, i.e. that 3
rd
port
is an EtherSound “OUT” port, and ports A and B are redundant “IN” ports.
The two redundant links have to receive the same EtherSound stream. They have to be
plugged to an AVRed-ES100 “IN”, or another AVY16-ES100 configured in “Redundant IN”
mode.
AVY16-ES100 AVY16-ES100
Mixing control &
Remote monitoring
PC
FOH STAGE
Redundant links taking
two different paths
AVY16-ES100
AD8HR
AES/EBU
AD8HR
AES/EBU
AD8HR
AES/EBU
AD8HR
AES/EBU
RS232
RS422
RS422
RS422
NAI48
In this example, first AVY16-ES100 is set in “Standard 3
rd
port” mode. Second one is set
in “Redundant IN” mode. Third one is set in “Redundant OUT” mode. Thanks to this
configuration, link between FOH and Stage is secured by using a dual redundant path,
without using AVRed-ES100.
As soon as one link becomes faulty or has a quality drop, card will automatically switch to
the other link, assuming its quality is better than the defective link.
Thanks to the ultra-low latency fault detection, no audio default can be heard in case of
broken or poor quality link.