User`s manual

AVS-ESMonitor – User’s Manual AuviTran 28
11-9 Routing Page
Routing page allows user to select EtherSound channel for each input and output (when
available) of selected device.
Channel assignment enables user to quickly set all inputs or outputs (depending on which
channel is selected) to same EtherSound channel, starting from selected EtherSound
channel or ending to a specific EtherSound channel. You can also mute all inputs or
outputs of selected device using Mute buttons.
On left side of grid, you can set aliases for each outputs and inputs of device. Thanks to
this feature, you will find easily and quickly what is connected to your different
EtherSound devices.
Global functions allow you to mute all outputs and inputs of device via a single button.
You can also refresh routing via a press on “Refresh” button. You are able to hide/show
alias column to enlarge EtherSound channel display.
In addition, you can get information on Bi-Directional status of device (whether it is
available, active or unavailable). Loop-back button lets you set the device as start of
loop-back mode for Bi-Directional EtherSound.
Thanks to the grid, you can directly assign EtherSound channel to input or output of
device by a simple click on the desired patch. Left click allows you to set for downstream,
while right click allows you to set upstream EtherSound channel (only bidirectional device
when available).
Device Output Patch
Device Input Patch
Output
Number
Input
Number
On left Click:
On left Click:
Patch device output 5
from downstream channel 13
On left Click:
On left Click:
Patch device Input 4
to downstream channel 28
Routing page overview for Mono directional device