User`s manual
AVM500-ES User’s Manual v2.1 AuviTran 2010
9
3 TECHNICAL SPECIFICATIONS
General
Size 483 x 253 x 44mm (19’ rack / 1U Height)
Power Consumption <50 Watts
Main Power Supply 100-240VAC 50/60Hz 1.5A Max
DC supply (Auxiliary) 5Vdc 5A max – 12Vdc 2A max
Auxiliary Power Supply 100-240V~ 47-63Hz 1.35A / +5Vdc 5A ; +12Vdc 2A
Storage: Temp/Humidity - 5°C to 70°C / Max 95% (non-condensing)
Operating: Temp/Humidity 5°C to 40°C / 5% to 90% (non-condensing)
Front Panel Networks and links Rx and Tx Activities; Active synch running ; Power Main, Aux and On Display
Rear Panel 1 IEC Power inlet; 7 Neutrik EtherCon RJ45; 1x6 poles Euroblock Connector for Aux power supply; 1 BNC for word
clock synch in; 1 DB9 connector for Serial Port
AVM500-ES Features
EtherSound Network Segment 5 EtherSound Network Segments interconnections : A (In, Out), B, C, D, E
EtherSound IN Port 1 EtherSound IN Port: AIN
EtherSound OUT Port 5 EtherSound OUT Ports: AOUT, B, C, D and E
ES-100 to ES-100 Latency 6 samples (125µs at 48 kHz)
Digital Audio Channels 320 (5 x 64) Input Audio channels and 320 (5 x 64) Output Audio channels
Matrix / Patch size 320x320 full cross matrix with remote control patch via EtherSound
Any individual output audio channel can be muted or patched to any of the 320 available Input audio channels
Remote control Via EtherSound of from Ethernet PC remote link
Other I/O RS232 serial port
Clock Synchronisation mode 48 kHz local clock (when Primary Master) or EtherSound Network (When not PM)
Word clock In used for synchronisation
Temp / Fan monitoring
Temp Monitoring Network Monitoring of Temperature inside the Box
PSU Monitoring Network Monitoring of PSU Failure for Main and Aux power supply
2 Fan Control modes Automatically Controlled by internal Temperature
Off
Development and Integration Environment
OS Supported Windows XP
ES-Monitor ES-Monitor enables to remotely set, control and monitor an EtherSound network and provides enhanced property
pages to manage the AVM500-ES specific parameters.
Remote Network Management Links status, Power supply status (Main, Aux), Temperature monitoring , Fan remote control and PSU Aux/Main
remote control