User guide

Commissioning Handbook, AutroSafe Interactive Fire Alarm System, Release 3, P-ASAFE/EE Rev. E, 2005-02-16,
Autronica Fire and Security AS
Page 10
4.1.2 Before You Begin
Make sure that the mains power is OFF.
Make sure that the mains inlet and the batteries are disconnected.
Make sure that fuse F1 and F2 on the Power Supply BSS-103A/02
are removed.
If external battery connection is used (external battery cabinet),
make sure that the battery fuses in the connection block are
removed as shown in the illustration below.
Before verifying the system, all parts in all system units must be
installed and properly connected:
All internal cabling in all system units must be done.
The mounting plate and all IO modules in the Fire Alarm Control
Panel and Controller must be installed in cabinet.
All external connections in the Fire Alarm Control Panel and
Controller (to detector loops, other input / output connections) must
be made before the 0V to Protective Earth resistance is verified.
The connection to Protective Earth in the Fire Alarm Control Panel
and Controller (to the mains inlet) must be made.
!