Owner`s manual

10
If the Host is not found within 3 minutes, the FOB will
automatically turn off to conserve battery power
The FOB communicates with the Host every 0.5 seconds
o If the Fob is turned on and the ON/OFF switch is held for more
than 2 seconds, the unit goes into an alarm mode. An alarm
trips the actuator, audible alarm and flashing LEDs
LED will go steady RED
NOTE
You cannot turn off the FOB with the power button on the FOB. The
FOBs will automatically go off 3 minutes after no communication with the
HOST.
FOB LED
o FOB OFF LED OFF
o FOB ON, Unregistered LED steady GREEN
o FOB ON, low batteries LED flashing AMBER each 2 sec
o FOB ON, batteries bad LED steady RED
o FOB ON, Registered LED Flashing GREEN each 4 sec
If a registered FOB goes out of range or the signal to the
Host is interrupted, the LED will change to Steady GREEN
until the FOB is re-registered with the Host
If no Host is found after 3 minutes, FOB will turn itself OFF
FOBs and Settings
The AUTOTETHER
TM
Host can monitor a maximum of four (4) FOBs
simultaneously. The Host and FOBs come channelized and pre-set from
the factory for normal operation. Once the AUTOTETHER
TM
system is
properly installed and activated, the FOBs and Host communicate with
each other every 0.5 seconds. If that communication is interrupted, the
alarm mode sounds and for the operator (yellow) FOB the kill switch
actuator is triggered to stop the vessel’s engine(s).
For proper AUTOTETHER
TM
operation and to prevent false alarms and
inadvertent engine shutdown, it is critical that the FOBs be worn
correctly by the vessel’s operator and the passengers.
The FOB should be worn so that it has uninterrupted communication
with the host