4.2 Maintenance schedule for QAS 45 Pd and QAS 60 Pd
(1) Change coolant every 5 years.
(2) Gaskets rocker cover can be re-used. New gasket can be ordered with
partnumber 2914 9845 00.
4.3 Engine maintenance
Refer to the engine’s operator manual for full maintenance
schedule.
4.4 (*) Measuring the alternator insulation
resistance
A 500 V megger is required to measure the alternator insulation
resistance.
If the N-terminal is connected to the earthing system, it must be
disconnected from the earth terminal. Disconnect the AVR.
Connect the megger between the earth terminal and terminal L1
and generate a voltage of 500 V. The scale must indicate a
resistance of at least 5 M.
Refer to the alternator operating and maintenance instructions for
more details.
Before carrying out any maintenance activity, check that the starter switch is in position O and that no electrical power is
present on the terminals.
4.2.1 Maintenance schedule
Daily 500 hours or
yearly
1000 hours
Service pak
- 2912 4411 05 -
For the most important subassemblies, Atlas Copco has developed service kits that combine all wear parts. These service kits offer you the bene-
fits of genuine parts, save on administration costs and are offered at reduced price, compared to the loose components. Refer to the parts list for
more information on the contents of the service kits.
Air/fuel/coolant & oil leakage Check Check Check
Electrolyte level and terminals of battery Check Check
Fixation of hoses, cables and pipes Check Check
Oil and coolant level Check Check Check
Coolers Check and
clean externally
Check and
clean externally
Check and
clean externally
Condition of cooling fan assembly Check Check Check
Tension and condition of the drive belt Check Check Check
Door hinges and locks Grease Grease
Engine oil Replace Replace
Engine oil filter Replace Replace
Fuel filter element Replace Replace
Fuel prefilter element Replace Replace
Water in fuel filter Drain Drain Drain
Air cleaner and dust bowl Clean Clean Clean
Air filter element Change Change
Safety cartridge Replace Replace
Engine inlet and outlet valves (2) Check/Adjust if necessary
Alternator and starter motor Check
Electrical system: security of cables and wear Check
Mechanical links Grease Grease
Condition of vibration dampers Check Check
Alternator insulation resistance Measure Measure
Glycol level in coolant (1) Check Check
PH level of engine coolant Check Check
Filter closed breather system Replace Replace
Inspection by Atlas Copco Service technician
!
!