Operating instructions

Commands Communication protocol
32 KNF Flodos CP_SIMDOS02_EN_01_166851
9.1.19 LCD display contrast
Sets the contrast level of the LCD display.
LCnnn
LC
nnn (3 digits, right adjusted)
LC060 LCD Contrast 60%
n Function
000 ... 100 LCD display contrast setting
100 Maximum accepted value (NACK if higher)
000 Minimum accepted value (NACK if lower)
040 (Factory default)
?LC
nnn (3 digits, right adjusted)
Transmit ?LC
Receive LC040 LCD Contrast 40% (default setting)
nnn Meaning
000…100 LCD display contrast setting
Display on Pump User Interface:
nnn Display
000…100 Contrast “nnn”
Value of LC is saved
Value of LC is saved
Take notice of the limits!
Summary:
Set command
Command string:
Parameter name:
Parameter value:
Example:
Read command
Command string:
Answer:
Example:
Power OFF behavior:
Auto-start Power OFF behavior:
Remarks: