9.1.13 Digital input 2 function
Selects the function of the digital input 2.
L2nn
L2
nn (2 digits, right adjusted)
L201 ⇒ Digital input 2, is configured for level controlled
Start/stop signals
nn Function
00 Signal 2: Off (Factory default)
01
level controlled: Start/stop signal
06 edge controlled: Start/stop signal
08
Pump Error reset & Pump Stop on signal edge.
09 Prime/Drain on signal level and error reset on signal edge
10 Error reset on signal edge and Prime/Drain after 1 second
on signal level
Summary:
Set command
Command string:
Parameter name:
Parameter value:
Example:
Logic level
active [1]
not active [0]
Error reset
t
L2 = 08
active [1]
not active [0]
Error reset
t
L2 = 09
Prime/Drain
active [1]
not active [0]
Error reset
t
L2 = 10
Prime/Drain
1s