Product data

SRN FRU List Problem
807-201 SCSI interface card assembly (60%)
(SCSI Interface Card Assemblyon
page 97)
SCSI attachment (40%) (using-system
service information)
Description: A device configuration error has occurred.
Action: Exchange the FRUs for new FRUs.
807-202 SCSI interface card assembly (60%)
(SCSI Interface Card Assemblyon
page 97)
SCSI attachment (40%) (using-system
service information)
Description: The 2104 enclosure failed to open.
Action: Exchange the FRUs for new FRUs.
807-203 SCSI interface card assembly (60%)
(SCSI Interface Card Assemblyon
page 97)
SCSI attachment (40%) (using-system
service information)
Description: The 2104 enclosure failed to return inquiry
data.
Action:
1. Observe the switch card assembly. Ensure that:
v Switch 3 (Enable Enclosure Services) is set to On.
v Switch 4 (Select Enclosure Services) is set to On.
2. Go to MAP 2010: 2104 STARTon page 44.
3. If the problem remains, exchange the FRUs for new
FRUs.
807-204 Fan-and-power-supply assembly
(45%) (Fan-and-Power-Supply
Assemblieson page 89)
Fan assembly (45%) (Fan Assembly
on page 94)
SCSI interface card assembly (4%)
(SCSI Interface Card Assemblyon
page 97)
Switch card assembly (3%) (Switch
Card Assemblyon page 102)
Frame assembly (3%) (Frame
Assemblyon page 106)
Description: A 2104 has detected a noncritical enclosure
failure.
Action: Go to MAP 2010: 2104 STARTon page 44. If the
problem remains, exchange the FRUs for new FRUs.
Chapter 2. Problem Determination Procedures
41