Product data

The SRNs
SRN FRU List Problem
807-12X Fan-and-power-supply assembly
(90%) (Fan-and-Power-Supply
Assemblieson page 89)
SCSI interface card assembly (5%)
(SCSI Interface Card Assemblyon
page 97)
Frame assembly (5%) (Frame
Assemblyon page 106)
Description: A power supply has failed. The diagnostic
message indicates the specific position of the failing FRU
(for example, Power Supply (n)).
Action: Exchange the FRU for a new FRU.
807-13X Fan assembly (90%) (Fan Assembly
on page 94)
SCSI interface card assembly (5%)
(SCSI Interface Card Assemblyon
page 97)
Frame assembly (5%) (Frame
Assemblyon page 106)
Description: The fan assembly has failed. The diagnostic
message indicates the specific position of the failing FRU
(for example, Fan (n)).
Action: Exchange the FRU for a new FRU.
807-148 None Description: Temperature warning.
Action: Take action to bring the ambient temperature inside
the specified limits (see Environmenton page 23). If the
problem remains, exchange the SCSI interface card for a
new one (see SCSI Interface Card Assemblyon page 97).
807-149 None Description: Critical temperature warning.
Action: Take action to bring the ambient temperature inside
the specified limits (see Environmenton page 23). If the
problem remains, exchange the SCSI interface card for a
new one (see SCSI Interface Card Assemblyon page 97).
807-17X SCSI interface card assembly (100%)
(SCSI Interface Card Assemblyon
page 97)
Description: A SCSI interface card has failed. The diagnostic
message indicates the specific position of the failing FRU
(for example, Enclosure Services (n)).
Action: Exchange the FRU for a new FRU.
807-180 Switch card assembly (90%) (Switch
Card Assemblyon page 102)
SCSI interface card assembly (5%)
(SCSI Interface Card Assemblyon
page 97)
Frame assembly (5%) (Frame
Assemblyon page 106)
Description: Switch card assembly failure.
Action: Exchange the FRUs for new FRUs.
40 2104 Service Guide