Product data

Service Inspection Guide
This inspection guide helps you to identify possible unsafe conditions on 2104s. Each
2104 has the necessary safety items installed to protect users and service personnel
from injury. This guide addresses only those items. You should use your good
judgment, however, to identify possible safety hazards that are not covered by this
guide.
If any unsafe conditions are present, you must determine how serious the possible
hazard could be, and whether you should continue without first correcting the problem.
Consider the following conditions and the safety hazards they present:
v Electrical hazards (especially primary power): Primary voltage on the frame can
cause serious or lethal electrical shock.
v Mechanical hazards: Loose or missing items (for example, nuts and screws) can
cause serious injury.
Using the following inspection checklist as a guide, inspect the 2104 for unsafe
conditions. See, if necessary, any suitable safety publications.
Inspection Checklist
1. Remove all power from the 2104 (see All Poweron page 71).
2. Check the frame for damage (loose, broken, or sharp edges).
3. Check the power cables and ensure that:
a. The third-wire ground connector is in good condition. Use a meter to check that
the third-wire ground continuity is 0.1 ohm or less between the external ground
pin and the frame ground.
b. The insulation is not worn or damaged.
4. Check for any obvious nonstandard changes. Use good judgment about the safety
of any such changes.
5. Check inside the 2104 for any obvious unsafe conditions, such as metal particles,
water or other fluids, or marks of overheating, fire, or smoke damage.
6. Check for worn, damaged, or pinched cables.
7. Ensure that the voltage specified on the product-information label matches the
specified voltage of the electrical power outlet. If necessary, verify the voltage.
8. Inspect the fan-and-power-supply assemblies, and check that the fasteners in the
cover of the power-supply unit (screws or rivets) have not been removed or
disturbed.
9. Before connecting the 2104 to the using system, check the grounding as described
in Checking the Grounding of the 2104on page 32.
Chapter 1. Reference Information 31