Specifications

KAVT7009-E
Memory became insufficient. (maintenance-information)
Memory became insufficient. The job terminates.
(S)
Terminates the job abnormally due to insufficient memory.
(O)
Check whether there is sufficient memory for executing the program. Then, use JP1/AJS3 - View to examine the
event job that caused the error, and then re-execute that job.
KAVT7010-E
An attempt to start the timer monitoring process failed. (maintenance-information) (maintenance-information)
An attempt to start the execution interval control process has failed.
(S)
Terminates the process because an error that prevents further processing occurred during startup of the execution
interval control process. An Interval Control job cannot be monitored.
(O)
Make sure that resources are sufficient, and then restart JP1/AJS3.
KAVT7011-E
An attempt to obtain pipe data failed. (maintenance-information) (maintenance-information)
The execution interval control process terminates because an error occurred during inter-process communication with
the agent process.
(S)
Terminates the execution interval control process because an error occurred during inter-process communication
with the agent process. An Interval Control job cannot be monitored.
(O)
Check the following:
Check whether system resources are sufficient.
Check whether the directory created at JP1/AJS3 installation was unintentionally deleted.
After the check, restart JP1/AJS3.
KAVT7012-E
An attempt to send pipe data failed. (
maintenance-information) (maintenance-information)
Interprocess communication with the agent has failed.
2. Messages
Job Management Partner 1/Automatic Job Management System 3 Messages 1
755