Specifications

(O)
Check whether JP1/AJS3 is installed correctly and whether the information is correctly set for the environment
setting parameters to be used for mail system linkage. For details, see 2.3.4 Setting up the environment for the mail
system linkage in the Job Management Partner 1/Automatic Job Management System 3 Linkage Guide.
Also check whether Administrator permissions are set for the following accounts:
Account of the OS user to whom the JP1 user who logs in to JP1/AJS3 - View is mapped
Account of the OS user when an OS user is specified for the account of the JP1/AJS3 service
Account of the OS user set for the JP1/AJS3 Mail service when the mail linkage function is used on the service
If you cannot check the above items, contact the system administrator, and collect data (see 1.2.3 To the system
administrators).
KAVT3420-W
The data set for inheritance information (macro-variable-name-of-truncated-data) is too long and was truncated
to maximum-macro-variable-size bytes.
The data set for inheritance information was greater than the maximum size of the macro variable. The data was truncated
to the maximum size.
(S)
Continues processing.
(O)
Check whether the subsequent job operates correctly.
KAVT3451-I
The mail linkage communication process will now start.
The mail linkage communication process starts.
(S)
Continues processing.
KAVT3452-I
The mail linkage communication process started.
The mail linkage communication process has started.
(S)
Continues processing.
2. Messages
Job Management Partner 1/Automatic Job Management System 3 Messages 1
618