Specifications
A file with the specified monitoring condition was updated, but the sum of the size of the values specified in macro
variables exceeded 4,096 bytes.
(S)
The maximum amount of data that can be used for all macro variables per event is 4096 bytes (includes variable
names). If the macro variable data exceeds 4096 bytes, the system uses only the first 4096 bytes and continues
processing.
(O)
Check the execution status of the succeeding jobnet or job. If you find any problem, recheck the job definition.
KAVT2038-E
Monitoring can not be continued. Because the information on file of 2 Gbytes or more is contained in the status
passing option file. (file-name)
Monitoring cannot be continued because the file used for storing the inherited status contains information about a file
equal to or greater than 2 gigabytes.
(S)
Terminates the job abnormally.
(O)
Check whether the large file support option is set to no. If it is set to no, the large file support option may have been
enabled before JP1/AJS3 stopped and the status passing option for the Monitoring Files job may have been enabled.
• When the large file support option can be enabled:
Enable the large file support option, restart JP1/AJS3, and then re-execute the job. Note, however, that the statuses
of the files that were monitored before JP1/AJS3 stopped are not inherited.
To enable the large file support option, specify yes for the LARGEFILEUSE environment setting parameter.
For details about the environment setting parameters, see 2.9 Setting up JP1/AJS3 shared information in the Job
Management Partner 1/Automatic Job Management System 3 Configuration Guide 2.
• When the large file support option cannot be enabled:
Make sure that the file indicated in file-name or any file under the directory specified using the wildcard
characters is smaller than 2 gigabytes. Make sure that the size of the file to be monitored does not exceed 2
gigabytes during monitoring, and then re-execute the job. Note, however, that the statuses of the files that were
monitored before JP1/AJS3 stopped are not inherited.
For details about the conditions for inheriting the status using the status passing option for the Monitoring Files job,
see 7.6.2 Notes on the Monitoring Files job in the Job Management Partner 1/Automatic Job Management System
3 System Design (Work Tasks) Guide.
KAVT3001-I
Mail was received.
Mail was received.
(S)
Continues processing.
2. Messages
Job Management Partner 1/Automatic Job Management System 3 Messages 1
588