Specifications

(O)
Check the following:
Check whether system resources are sufficient.
Check whether the directory created at JP1/AJS3 installation was unintentionally deleted.
For a cluster system, check whether the setting of the status passing option for a Monitoring Files job between
the primary node and the secondary node matches.
For a cluster system that uses event jobs for DNS operation, check whether the setting for operation using the
FQDN format between the primary node and the secondary node matches.
For details about the conditions for inheriting the status using the status passing option for the Monitoring Files job,
see 7.6.2 Notes on the Monitoring Files job in the Job Management Partner 1/Automatic Job Management System
3 System Design (Work Tasks) Guide.
If this message appears when the condition necessary for inheriting the status is not satisfied, this means that the
file used for storing inherited status was deleted due to termination of the Monitoring Files job. Ignore the message
and continue the operation.
KAVT2035-E
The name of the file to be monitored includes an invalid character. (file-name, maintenance-information)
An invalid character is specified in the name of the file to be monitored.
(S)
An invalid character is specified in the name of the file to be monitored. Abnormally terminates the job.
(O)
Check whether the name of the file to be monitored is created using the character codes that JP1/AJS3 can recognize.
KAVT2036-W
The open file check is impossible because the monitoring target file has no write permission. (file-name,
maintenance-information, maintenance-information)
The system cannot perform an open file check for the file to be monitored because there is no permission to write into
the file. The system does not assume that the file monitoring condition is satisfied.
(S)
The system does not assume that the file monitoring condition is satisfied. Continues processing.
(O)
Give the JP1/AJS3 service account the permission to write into the file to be monitored. In Windows, if the read-
only checkbox for the file to be monitored is selected, deselect it.
KAVT2037-W
A macro variable exceeds 4096 bytes.
2. Messages
Job Management Partner 1/Automatic Job Management System 3 Messages 1
587