Specifications
KAVT0541-E
The pipe could not be written to. (process type=process-type maintenance-information)
An attempt to write to a pipe file used in the event/action control agent has failed.
(S)
Continues processing while the function of the process indicated in process-type is disabled.
process-type
0: Receive JP1 Event job, Monitoring Log Files job, or Monitoring Event Log job
1: Monitoring Files job
2: Receive MQ Message job
3: Email Reception Monitoring job
4: Interval Control job
5: Receive MSMQ Message job
(O)
Check the following, and then retry:
• Check whether system resources are sufficient.
• Check whether the user who started JP1/AJS3 has superuser privileges or has logged on as a member of the
Administrators group.
Check whether the directory created at JP1/AJS3 installation is unintentionally deleted. If the code indicated in
maintenance-information is -1, this means that the agent process has terminated. Restart JP1/AJS3 on the agent.
KAVT0542-E
The auxiliary file name could not be acquired. (maintenance-information)
An attempt to acquire a communication information file for a monitoring process used in the event/action control agent
has failed.
(S)
Places the job in the Ended abnormally status, and continues processing.
(O)
Check the following, and then retry:
• Check whether system resources are sufficient.
• Check whether the user who started JP1/AJS3 has superuser privileges or has logged on as a member of the
Administrators group.
• Check whether the directory created at JP1/AJS3 installation is unintentionally deleted.
KAVT0544-E
The auxiliary file could not be read. (auxiliary file=
auxiliary-file-name) (maintenance-information)
2. Messages
Job Management Partner 1/Automatic Job Management System 3 Messages 1
537