Specifications

KAVT0530-E
The end request for the pipe could not be written. (process type=process-type maintenance-information) (process
name=process-name, maintenance-information)
An attempt to write to a pipe file used in the event/action control agent has failed.
(S)
Continues processing while the function of the process indicated in process-type is disabled.
process-type
0: Receive JP1 Event job, Monitoring Log Files job, or Monitoring Event Log job
1: Monitoring Files job
2: Receive MQ Message job
3: Email Reception Monitoring job
4: Interval Control job
5: Receive MSMQ Message job
(O)
The process indicated in process-type may still remain in the system.
In UNIX, use the ps command to check whether the process remains in the system. If the process remains, use the
kill command to terminate it.
In Windows, restart the system.
Check the following, and then restart JP1/AJS3:
Check whether system resources are sufficient.
Check whether the user who started JP1/AJS3 has superuser privileges or has logged on as a member of the
Administrators group.
Check whether the directory created at JP1/AJS3 installation is unintentionally deleted.
KAVT0539-E
The auxiliary file could not be read. (auxiliary file=auxiliary-file-name) (maintenance-information)
An attempt to write to a communication information file for a monitoring process in the event/action control agent has
failed.
(S)
Places the job in the Ended abnormally status, and continues processing.
(O)
Check the following, and then retry:
Check whether system resources are sufficient.
Check whether the user who started JP1/AJS3 has superuser privileges or has logged on as a member of the
Administrators group.
Check whether the directory created at JP1/AJS3 installation is unintentionally deleted.
2. Messages
Job Management Partner 1/Automatic Job Management System 3 Messages 1