Specifications
For details on this time, see Table 2-3 in 2.2.2(5) Notes on manager/agent system configurations in the Job
Management Partner 1/Automatic Job Management System 3 System Design (Configuration) Guide.
(O)
A communication error may have occurred due to one of the following reasons. For a jobnet with start conditions
or an event job, no action is required because the data that caused the communication error will be resent
automatically after the predefined period of time:
• The network or the agent machine has stopped.
• A temporary communication error occurred.
• The event job attempted processing exceeding its throughput.
If a network error occurred, examine the cause of the error and correct it.
If the agent machine indicated in agent-host-name has stopped, restart it.
If a one-time communication error occurred due to heavily-loaded communications that are caused by too many
event jobs being processed at once, ignore the message and continue the operation. However, if this message
frequently appears, the throughput may be exceeded. See 3. Estimates in the Job Management Partner 1/Automatic
Job Management System 3 System Design (Configuration) Guide, and recheck the estimates for using event jobs.
KAVT0271-E
An attempt to get the IP address of the host (name-of-host-whose-IP-address-could-not-be-obtained) during the
start notification from the agent (name-of-host-notifying-startup-from-agent) failed. (maintenance-information)
During startup of the agent host, an attempt to start a jobnet with start conditions or an event job for the agent started
by the manager has failed.
(S)
A jobnet with start conditions or an event job that was being monitored on the host indicated by name-of-host-whose-
IP-address-could-not-be-obtained can no longer be monitored.
(O)
On the manager host, use the jp1ping command to check whether the IP address of the host indicated by name-
of-host-whose-IP-address-could-not-be-obtained can be obtained. For details on the jp1ping command, see the
Job Management Partner 1/Base User's Guide.
If the IP address cannot be obtained, specify the settings in the hosts file, jp1hosts information, or jp1hosts2
information on the manager host or in the DNS settings so that the correct address can be obtained by resolving the
name. Next, forcibly terminate the relevant jobnet with start conditions or event job, and then re-execute it.
KAVT0272-E
An attempt to get the IP address of the host (
name-of-host-whose-IP-address-could-not-be-obtained) during the
stop notification from the agent (name-of-host-notifying-termination-from-agent) failed. (maintenance-
information)
During termination of the agent host, an attempt to stop an event job for the agent started by the manager has failed.
(S)
The status of the event job being executed on the host indicated by name-of-host-whose-IP-address-could-not-be-
obtained remains now running.