Specifications
KAVS1896-E
A log file (file-name) error occurred.: maintenance-information-1 (maintenance-information-2)
An error occurred during processing required to open or write to the log file indicated in file-name.
(S)
• If this message is output during startup of a queueless agent service, the system continues startup of the service.
However, no log data is output to the log file indicated in file-name.
• If this message is output during execution of a queueless job, the system continues queueless job execution.
However, no log data about the queueless job is output to the log file indicated in file-name.
(O)
Take one of the following actions:
• If No such file or directory is indicated in maintenance-information-1, the log file indicated in file-
name might have been deleted. Check whether the log file exists. If it does not exist, restart the queueless agent
service.
• If Permission denied is indicated in maintenance-information-1, write and read permissions for the log
file indicated in file-name might have been changed. Change the permissions so that the user who started the
queueless agent service and the OS user who executes the queueless job can read and write to the log file indicated
in file-name. Then, restart the queueless agent service.
• If any message other than the above is indicated in maintenance-information-1, correct the error according to
the message, and then restart the queueless agent service.
If you cannot correct the problem by taking the above actions, contact the system administrator, and then collect
data (see 1.2.3 To the system administrators).
KAVS1897-E
An attempt to start the job (job-name).
An attempt to start the queueless job indicated in job-name has failed due to an internal error.
(S)
Places the queueless job indicated in job-name into Failed to start status or Ended abnormally status.
(O)
Re-execute the queueless job indicated in job-name that resulted in the error. If an attempt to start the queueless job
fails again, restart the queueless agent service, and then re-execute the queueless job indicated in job-name that
resulted in the error.
If the UAC function is enabled in Windows and the OS user who executed the job is a member of the Administrators
group, the Administrators permission might be disabled for the indicated job. Either execute the job by using the
built-in Administrator account, or enable the settings for executing jobs as a user with administrator permissions
when the UAC is enabled, and then execute the job. For details, see 6.2.22 Settings for executing jobs as a user with
administrator permissions when the UAC is enabled in the Job Management Partner 1/Automatic Job Management
System 3 Configuration Guide 1.
If you cannot correct the problem by taking the above actions, contact the system administrator, and then collect
data (see 1.2.3 To the system administrators).