Specifications
The system cannot display the status because the file system or device in JP1/AJS3 Console Agent at the monitoring
destination does not have sufficient free space for writing a file. Alternatively, the system cannot perform the operation.
(S)
Sets Unknown as the status of the object and continues processing if the error occurred during status acquisition. If
the error occurred during an operation, the system determines that the operation is an error and continues processing.
(O)
Delete unnecessary files in the JP1/AJS3 Console Agent host at the monitoring destination to increase free space.
KAVC6204-E
Resources became insufficient at the monitoring destination.
The system cannot display the status because a resource became insufficient in JP1/AJS3 Console Agent at the
monitoring destination. Alternatively, the system cannot perform the operation.
(S)
Sets Unknown as the status of the object and continues processing if the error occurred during status acquisition. If
the error occurred during an operation, the system determines that the operation is an error and continues processing.
(O)
Use log information such as the Windows event log or the syslog in the host for JP1/AJS3 Console Agent to examine
the error. Then correct the cause of the error according to the check results.
KAVC6211-E
Cannot connect because the number of connections exceeded the maximum at the monitoring destination.
The system cannot display the status because the number of connections to JP1/AJS3 Console Agent at the monitoring
destination exceeded the maximum and thus JP1/AJS3 Console Manager at the connection destination cannot connect
to JP1/AJS3 Console Agent at the monitoring destination.
(S)
Sets Unknown as the status of the object and continues processing.
(O)
If two or more JP1/AJS3 Console View programs are being used to monitor tasks in the same business root scope,
log off from the unnecessary instance of JP1/AJS3 Console View. If there are two or more objects to be monitored
on the same host, specify the same name for Host name for each monitored object.
You can change the maximum number of connections in the environment settings for JP1/AJS3 Console Agent. Set
a value in the MAXSESSION environment setting parameter.
KAVC6212-E
Communication access was denied at the monitoring destination.
2. Messages
Job Management Partner 1/Automatic Job Management System 3 Messages 1
172