Technical data

www.kawanlama.com
873
MEASURING AND TESTING EQUIPMENT
CABLE AND ELECTRIC APPLIANCE
Specication
AC A
400A(0~400A)
±1%rdg±3dgt[50/60Hz]
±2%rdg±3dgt[40Hz~1kHz]
2000A(0~1500A)
±1%rdg±3dgt[50/60Hz]
±3%rdg±3dgt[40Hz~1kHz]
2000A(1500~2000A)
±3.0%rdg[50/60Hz]
AC V
40/400/750V
±1%rdg±2dgt[50/60Hz]
±1.5%rdg±3dgt[40Hz~1kHz]
DC V 40/400/1000V ±1%rdg±2dgt
400Ω/4k/40k/400kΩ ±1.5%rdg±2dgt
Countinuity Buzzer buzzer sounds below 50±35Ω
Output Voltage 400/2000A DC400mV/200mV
Conductor Size (mm) Ø55 Max.
Safety Standard
IEC61010-1 CAT.III 600V CAT.II 1000V
IEC61010-2-031 IEC61010-2-032
Frequency Response 40Hz-1kHz
Withstand Voltage 5550V AC for 1 Minute
Power Source R6P (AA)(1.5V)x 2
Dimensions (mm) 247(L) x 105(W) x 49(D)
Weight (gr) 470 approx.
Accessories
7107(Test Leads) 8201 (Output Plug)
9094(Carrying Case) R6P(AA) x 2 Instruction
Manual
Optional 8004/8008(Multi-Tran) 7014(Output Cord)
KEW ANALOGUE CLAMP METER
Model 2002PA
Type
Description
MODEL 2002PA
Kew Analogue Clamp Meters
KEW AC/DC DIGITAL
CLAMP METER
Model 2003A
Specication
AC A
400A/2000A(0-1000A)
±1.5%rdg±2dgt[50/60Hz] ±3%rdg±4dgt[40-
500Hz] ±5%rdg±4dgt[500Hz-1kHz]
2000A(1001-2000A)
±3%rdg±2dgt[50/60Hz]
AC V
400/750V
±1.5%rdg±2dgt[50/60Hz]
±1.5%rdg±4dgt[40-1kHz]
DC A 400/2000A ±1.5%rdg±2dgt
DC V 400/1000V ±1%rdg±2dgt
400/4000Ω ±1.5%rdg±2dgt
Countinuity Buzzer (Ω) buzzer sounds below 50±35
Output Voltage 400/2000A DC400mV/200mV
Conductor Size (mm) Ø55 Max.
Applicable Standard
IEC61010-1 CAT.III 600V CAT.II 1000V
IEC61010-2-031 IE61010-2-032
Frequency Response 40Hz-1kHz
Withstand Voltage 6880V AC for 5 seconds
Power Source R6P(AA)(1.5V) x2
Dimensions (mm) 250(L) x 105(W) x 49(D)
Weight (gr) 530 approx.
Accessories
7107(Test Leads) 8201(Output Plug)
9094(Carrying Case) R6P(AA) x2 Instruction
Manual
Optional
8004/8008(Multi-Tran)(AC only)
7014(Output Cord)
Type
Description
MODEL 2003A
Kew Ac/Dc Digital Clamp Meters
Benets :
• CanmeasurelargeACcurrentupto2000A.
•Peakholdfunction
•55mm-dialargeteardropshapedjaws
Benets :
• EquippedtomeasurebothACandDCcurrentwithtransformerjawsof
large diameter
•CanmeasureACandDCcurrentsupto2000A
• Outputterminalforconnectiontorecorders
• AC/DCvoltage,resistancemeasurementandcontinuityfunctionsalso
available