Technical data
MEASURING AND TESTING EQUIPMENT
862
15
Features :
• It can use to analyzed material with metode of Non
Destructive test
• Has a Compact Design resulting in small footprint
• The Measuring head contains all mechanical and
electronic component required for x-ray uorescence
analysis
• Communication with the control and evaluation
computer is carried out via a standard RS 232
interface
Technical Specication
Detector
Semiconductor with Peltier Cooling (-30
0
C
(-34,4
0
F)), Energi Resolution 200 eV
Analysis Range From Al (z= 13) To U (Z = 92)
Motor Driven Collimator
Setting
Four Round Collimators with Diameter of
0,2, 0,6, 1, and 2mm
Power Connection 110 v / 230 v, 300 W
Fischer scope x ray xan is an equipment to analize content of
material in units of percentage.
Order No. Type Description
FIZ000002 - Fischer Scope X Ray Xan
FISCHERSCOPE X-RAY XAN
COATING, MATERIAL ANALYSIS AND
POROSITY TESTING
Result spectrum of a gold analysis
Features :
• Low-energy, therefore safe, high voltage
• High voltage generation in the test head
• Two test head versions with test voltsges ranges: 0.3 to 3kV and 2.5 to
25 kV can be connected
• Extensive electrode selection
• Continuously adjustable test voltage
• Display of the test voltage that is present directly at the electrode
Order No. Description
EV0000025 80-440-0002 Porotest 7 Basic Unit
EV0000049 80-441-0002 P7 Hightension Electrodes F/Porotest 7
Is an Equipment for Detection of pinholes and aws in
insulating coating like : Paint, Plastics and enamel
POROTEST 7
Technical Data
Test Voltage (Continuously
Adjustable Range):
Test Head HV3PK: 0.3 ... 3 kVDC Test Head HV20PK: 2.5 ...
25 kVDC
Test Voltage Display Error: < 5%
Environmental Conditions
During Operation:
0 ... +40°C (32 ... +104°F) and 0 ... 60% RH, No Condensation
On Test Surface
Storage Temperature: 0 ... +60°C (32 ... +140°F)
Standards:
Instrument Safety VDE 0411/1
Pasture Fence Ordinance
Test: DIN 55670, DIN 28055-2, DIN 4753-3