Technical data
MEASURING AND TESTING EQUIPMENT
860
15
COULOSCOPE
Features :
• Simplechoiceofdeplatingrateandtestareasize
• Availabletestareasizes:ø3.2(128),2.2(88)and1.5(60)mm(mils).
0.6mm
(24 mils) additional for stand V18
• Deplatingrateadjustablebetween0.1and50μm/min
• StandV18:controlledllingandemptyingofthecellbymeansofa
pump. Multiple measurements with one cell lling and warning when
the electrolyte becomes saturated.
• Zoomfunctiontomagnifyinterestingplotsections
•Selectablemeasurementunits:μmormils
Couloscope CMS It is the ideal instrument for measuring the thickness
of virtually any metallic coating on metallic or non-metallic substrates,
especially also of multiple coatings, if non-destructive methods cannot
or need not to be used.
Start of deplating the coating End of deplatingCoating deplating in process
COATING AND MATERIAL ANALYSIS
COATING THICKNESS GAUGE
Coating Thickness Gauge
Features:
• 2measuringmodes:continous/
single
• 2shutdownmodes:manual/
automatic
• Directtestingmodeandblock
statistic mode (APPL/BATCH)
• Directprintoutofstatistical
values
• DataviewtoconnectwithPC
• 495datacanbestored
Order No. Type Description
KW0600331 KW06-331 Coating Thickness Gauge
Specication
Measuring Range
0~1250 µm with Standard Probe
F1.N1 (10.000m Max. )
Tolerance
F1:±(1 µm + 3% Reading)
N1:±(1.5 µm + 3% of Reading)
Resolution Alphanumeric with 4 Large Digits
Operation Language English
Standards DIN, ISO, ASTM, BS
Min. Measuring Area F1: (Standard Probe)
Min. Curvature Radius (mm) Type F: 0,5, type N: 50
Calibration Zero and Foil Calibration
Statistics
Number Of Measurements, Mean,
Standard
Deviation, Maximum and Minimum
of 3000
Readings
Data Memory 495 Measuring Data
Limits Adjustable with Acoustic Album
Interface RS-232
Operating Temperatur (
°
C) 0-40
Power Supply (V) Nicd Rechargeable Batteries 1.25
Dimensions (mm) 270 x 86 x 47
Weight (gr) Approx.530
FERROUS AND NON FERROUS
Accessories
•Probe 1
•Charger 1
•Calibrationfoils 1
•Instructionmanual 1
•Carryingcase 1