Technical data
MEASURING AND TESTING EQUIPMENT
846
15
WELDING AND ROHS TESTING
Features :
•Non-destructivemeasurementoftheferritecontentinarangeof0.1to110FNor
0.1 to 80% Fe in austenitic and duplex steel
•Onlyonecalibrationrequiredfortheentirepracticallyrelevantmeasurement
range from 0.1 to about 90 FN.
Measurement accuracy according to ANSI/AWS A4.2M/A4.2:1997 standard
•CalibrationwithstandardstraceabletoTWIsecondarystandardsorwith
customer-speci c standards
•MeasurementunitsselectablebetweenWRC-FNand%Fe
•Memoryforupto20,000readings
•Upto100applicationsformeasuringapplicationspeciccalibrations
•Displayofstatisticalcommoncharacteristicvaluessuchasmeanvalue,standard
deviation, min, Max. , range in the block and nal results. Output of characteristic
variance-analytical values
•Graphicalmeasurementdisplayasahistogramwithagaussianplot
•Matrixmeasuringmodeforconnectedmulti-pointmeasurements,e.g.,ina
pre-de ned surface array
•Applicationlinkingmode:abilityforcommonnormalization/calibrationof
applications
•DesignationsforapplicationsthroughtheoptionalPCprogramMP-Name.
•DatatransfertoaPCintoanexcelspreadsheetwiththeoptionalPCprogram
PC-Datex
Ferritscope measures the ferrite content in austenitic and duplex
steel according to the magnetic induction method. All magnetic com-
ponents of the otherwise non-magnetic structure are recognized, that is,
in addition to delta ferrite and other ferritic components transformation
martensite is also recognized. The instrument is suitable for measurements
according to the Basler Standard or according to DIN 32514-1. Areas of ap-
plication are on-site measurements, e.g., of austenitic claddings as well as
weld seams in stainless steel pipes, containers, boilers or other products
made of austenitic or duplex steel.
FERRISTCOPE FMP30
Microprocessor Digital Anemometer W/Thermometer
RoHS TESTER
Fischerscope X-ray XAN for RoHS testing
X-Ray Spectrometer
for Quantitative Analysis
Particularly simple and quick handling of the parts to
be measured is possible due to the special design
with the primary X-ray beam and the detector underneath
the specimen support. Suitable for all elds
of application in particular for RoHS/WEEE and precious
metal analysis. With semiconductor detector
and WinFTM® V.6 software.
Spectrometer for coating thickness measurement
and materials analysis.
Measurement method: energy dispersive X-ray
uorescence (EDXRF) according to DIN EN ISO 3497
and ASTM B 568.
RoHS/WEEE
• VeryreliablemeasurementofPb,Hg,Cd,BrandCr.Theachiev
able detection limits are 2 ppm for lead, and 10 ppm for cad
mium.
• TheRoHS/WEEElimitvaluesof1000ppm(Pb)and100ppm
(Cd) can be veried reliably.
•Plasticsamplescanbeanalyzedcorrectlyregardlessoftheir
thickness.
• Evensmallelectronicscomponentsorcoatingsystemson
printed conductors are analyzed with point precision.
Order No. Description
F10000205 SK WG-1 Welding Gauge (M)
WG-1
WG-2
Application
WELDING GAUGE