Technical data

www.kawanlama.com
839
MEASURING AND TESTING EQUIPMENT
Features :
• ThersthardnesstesterthatconnectsdirectlytoaPCandtothe
portable Equotip 3 testing platform
• Theuserisinstructedpreciselywhentoapplyandreleasethetest
loads; the displayed signal curve enables the user to judge the quality
of the measurement
• Measuringclamp,magneticfeet,andspecialfeetadapttomostsample
shapes
• TheincludedPCsoftwarepackageEquolink3addressesprofessional
data management needs
This equipment is used to measure hardness of metal ferrous and non-
ferrous for thin material.
EQUOSTAT 3
Equotip 3 Hardness Measuring System
Features :
•Goodforallmaterials
•Idealforproductionleveltesting
•Bestsuitedforon-sitetestingofheavy,bigoralreadyinstalledparts
•Handyfordiculttoaccessorconnedtestlocations
•Automaticsensingandcompensationforimpactdirection
•Excellentformaterialselectionandacceptancetests
•Easytouseandaccurateoncurvedtestsurfaces(R>10mm/0.4inches)
This Equipment is used to measure hardness of metal ferrous and non-
ferrous without statistic.
Order No. Type Description
PC0000088 35210002 Equotip Piccolo 2 Unit D with Test Block D
EQUOTIP PICCOLO 2
®
Probe Setup
Minimum Test
Piece Thickness
Max. Imum Test
Piece Thickness
Test Piece Surface
Condition
Surface Curvature
Max. Test Piece
Hardness
Minimum Spacing
50 N Probe with Clamp
1mm At ~20 Hb
130mm At ~70
Hrc
41mm
Recommended Mean
Surface Roughness Ra
< 2mm to Minimize
Data Scatter
70hrc
Three Times The
Diameter of a Test
Indentation
50 N Probe with Round
Standard Foot (Ø = 42
mm)
N/A
Foot To Be Used for
Plane Surfaces
50 N Probe with Tripod
Very Small Curva-
tures Acceptable
50 N Probe with Long
Foot
Very Small Curva-
tures Acceptable
Recommended <
60hrc
50 N Probe with
Special Feet
18 - 70mm Radius of
Curvature or 70mm
- ∞
70hrc
Equostat 3 Probe
Measuring Range 19-70 HRC; 19-70 HMMRC; 67-638 HB; 35-950 HV; 60-86 HRA; 29-107 HRB; 225-2250 MPa; 69-94 HR15N; 88-96 HR15T
Resolution 0.1 m; 0.1 HRA; 0.1 HRB; 0.1 HRC; 0.1 HRE; 0.1 HRH; 0.1 HR15N; 0.1 HR15T; 1 HB; 1 HV; 0.1 HS; 1 MPa
Measuring Accuracy ~ ± 1.5 HRC Over Entire Range
Max. Imum Test Hardness 70 HRC
Test Direction Any Direction (No Correction Required)
Test Loads 10 N / 50 N (probe 50 N)
Diamond Indenter angle 100.0° ± 0.5°
With Impact Device D With Impact device DL
Measuring Range 150-950 HLD 250-970 HLDL
Instrument Dimensions 147.5 x 44 x 20mm (5.71 x 1.75 x 0.79 inches) 203 x 44 x 20mm (7.99 x 1.75 x 0.79 inches)
Instrument Weight 142g (5 ounces) 152g (5.4 ounces)
General Specications (Applicable to Both Equotip Piccolo 2 and Equotip Bambino 2)
Conversions
80-955 HV, 81-678 HB, 20-70 HRC, 38-102 HRB,
30-100 HS (Equotip Piccolo 2 only: 274-2193 N/mm2)
Resolution 1 HLD/HLDL, 1 HV, 1 HB; 0.1 HRC, 0.1 HRB,0.1 HS (Equotip Piccolo 2 only: 1 N/mm2 Rm)
Measuring Accuracy ± 4 HLD/HLDL (0.5% at 800 HLD/HLDL)
Max. Imum Test Hardness 890 HLD (955 HV, 68 HRC)
Impact Direction / Energy Automatic compensation/11Nmm
Ball Indenter Tungsten carbide (approx. 1’500 HV), 3mm (0.12 inches) diameter
Housing Scratch-Proof, Hard-Coated Zinc Alloy
Battery Rechargeable Li Ion, Operation Period Over 20’000 Impacts, Charging Current 100 Ma
Integrated Memory Non-volatile, RAM 32 kBytes, ~ 2’000 Measured Values (Equotip Piccolo 2 only)
Operating Conditions Temperature: -10 to +60 °C (14 to 140 °F), Humidity: 90% Max.
HARDNESS AND CONCRETE