Installation guide
P. 16 Installation Guide AS-2360TW
Programming Options
MODE 1 * INDICATES DEFAULT SETTING
FUNCTION 1 – Ignition-controlled Door Locks
OPTION 1* Ignition Lock DISABLED
OPTION 2 Ignition Lock ENABLED
OPTION 3 Ignition UNLOCK ONLY
OPTION 4 Ignition LOCK ONLY
FUNCTION 2 – Secure Lock
OPTION 1* Secure Lock DISABLED (1-sec. Disarm pulse)
OPTION 2 Secure Lock ENABLED in Smart Secure Lock Mode
OPTION 3 Secure Lock DISABLED (1/2-sec. Disarm pulse)
OPTION 4 Secure Lock ENABLED in Standard Mode
OPTION 5 Secure Lock
(no rearm pulse when ignition and the ground out when running are ON)
FUNCTION 3 – Starter Kill Passive / Active Arming
OPTION 1* PASSIVE Arming (60 sec.)
OPTION 2 ACTIVE Arming
OPTION 3 PASSIVE Arming (3 min.)
FUNCTION 4 – Door lock pulse timing
OPTION 1* 7/10-sec. lock/unlock pulses
OPTION 2 4-sec. lock/unlock pulses
OPTION 3 7/10-sec. lock pulse and two 1/4-sec. unlock pulses
OPTION 4 1/10-sec. lock/unlock pulses
FUNCTION 5 – LED flashing
OPTION 1* ENABLED (without starter kill Æ will flash only when ignition is OFF)
OPTION 2 DISABLED
OPTION 3 ENABLED (with starter kill Æ will flash when the starter kill engages.
This option should be selected ONLY if the starter kill is installed.)
MODE 2 * INDICATES DEFAULT SETTING
FUNCTION 1 – Safe Start.
OPTION 1 Safe Start ENABLED
OPTION 2* Safe Start DISABLED
OPTION 3 “Swap Start” – enhanced Safe Start Mode with extended safety:
To start the Engine: press the SHIFT button and then the LOCK button.
To trigger AUX 2: press the START/STOP button. Must have configured
option 1 or option 2 in mode 3 function 3.
FUNCTION 2 – Engine Run Time
OPTION 1 Run Time = 4 minutes in GAS mode / 9 minutes DIESEL mode
OPTION 2* Run Time = 15 minutes in GAS mode / 20 minutes DIESEL mode
OPTION 3 Run Time = 25 minutes in GAS mode / 30 minutes DIESEL mode
FUNCTION 3 – Turbo Mode
OPTION 1 Turbo Mode ENABLED
OPTION 2* Turbo Mode DISABLED
OPTION 3 Turbo Mode ENABLED
FUNCTION 4 – Engine type and Cold Weather Mode
OPTION 1 30-sec delay diesel mode with 20-minute run time in cold weather mode
OPTION 2* 1-sec delay gas mode with 4-minute run time in cold weather mode
OPTION 3 7-sec delay diesel mode with 9-minute run time in cold weather mode
OPTION 4 15-sec delay diesel mode with 9 minute run time in cold weather mode