Installation guide
P. 10 Installation Guide AS-2360TW
This wire provides a constant 500 mA
g
round output
while the module is runnin
g
. This output becomes
active at the same time as the i
g
nition and shuts off
when the module shuts down, e.g.: when the run
time has expired, when the
START/STOP button has
been pressed, etc. This output can be used to
activate external relays, bypass kits, etc.
10 WHITE
(–) Ground
Out
When
Running
Caution! If multiple rela
y
s or modules are connected
to the ground- out-when-running wire, make sure
the
y
are diode isolated from one another: feedback
may otherwise occur, causing damage to the vehicle.
This input should be used in vehicles with negative-
switching door pins or dome light circuits. Connect
to the dome light wire that tests ground when a door
is open.
11 GREY
(–) Negative
Door input
Caution! The installer should use either the positive
or the negative door input. Never use both of them
simultaneously.
It is essential that the module be connected in such a
way as will allow each one of the doors to turn off
ready mode: the driver-side door pin
does not constitute by itself a
sufficient connection.