Specifications
A - 6 RSLinx – Training Guide
The OPC client poll rate can over ride the RSLinx topic
poll rate
The information in this technote applies to:
Product:
RSLinx
Type:
Release Note
Technote ID:
R221
Package/Mod
ule(s):
RSLinx (All)
Modified:
12/28/98
Revision(s):
2.x
Fixed In
Revision:
N/A
Sub-
System(s):
DDE/OPC Server
Technical Note Details:
If the update rate specified by an OPC client is faster than the poll rate specified in
RSLinx. RSLinx will request data from the PLC as the update rate specified by the OPC
client
Example: If the poll rate in RSLinx is set to 1000ms, and the update rate of the OPC
client is set for 200ms then RSLinx will request data from the PLC every 200ms.
Example: If the poll rate in RSLinx is set to 200ms, and the update rate of the OPC
client is set for 1000ms then RSLinx will request data from the PLC every 200ms.
However, the OPC client will only request the data from RSLinx every 1000ms
Note: DDE links will update at the actual poll rate RSLinx uses. In the case where the
OPC client update rate is faster than the RSLinx poll rate, DDE clients will also be
updated at the rate of the OPC client
Legal Notice:
The information provided in the Rockwell Software Inc. (RSI) Knowledgebase is provided
"as is" without warranty of any kind. RSI disclaims all warranties, either expressed or implied
and in no event shall RSI be liable for any damages whatsoever including direct, indirect,
incidental, consequential, loss of profit or damage, even if RSI have been advised of the
possibility of such damages.
The foregoing limitation may not apply in those states that do not allow
the exclusion or limitation of liability for damages.