The GV-7i is an integrated inverter-charger-variable speed generator solution which has standard
factory setting to operate with a AGM battery set of 12V/[tbd]Ah, 24V/[tbd]Ah or 48V/[tbd]Ah. If
the auto start/stop cable is connected from the connection board of the WPC to the DDC remote
panel input, the auto-start/stop functionality can be enabled on the display.
Settings have been chosen to start the generator if the service set has a low voltage, or if the
power consumption is above a certain level. In the default settings, temperature compensation is
[not enabled] and the optional BSP (battery status processor) has not been included.
Important: to inhibit automatic starting and stopping of the generator at any time, select Manual
mode on the DDC remote panel. Refer to DDC remote panel manual.
The Whisper Power System Control Panel (PSCP) consists of two combined modules: the generator
control (upper part), also referred to as DDC remote panel, and the Inverter/Charger Control panel
also referred to as RCC panel.
This Quick settings document is meant to highlight the most important settings to cover 90% of the
installations and user first needs. For an explanation to operation the PSCP or complete settings of
the WPC, please refer to the manual. Most of the settings are determined once at installation.
Settings which are likely to be changed by the user under normal use are highlighted in the
headings.