Service manual

Operating Procedures
Illustration
(2) Remove the axial flow fan
Loosen the ball nuts fixing the axial
flow fan and remove the lock washer.
(See Fig. 7)
Pull outward to remove the axial flow
fan. (See Fig. 7)
(3) Remove the fan motor
Loosen the screws fixing the motor
support. Remove the motor support.
(See Fig. 8)
Ball nut
Fig.7
Motor support
Fig.8
Fig.9
48