Service manual
has responded to the last input, the system will exit this menu and display the normal turn-off interface.
After completing above setting, the system will display SAVE-ENERGY icon on the LCD when the unit is
turned on next time. In this case, no matter from the wired controller or remote controller, the user is
unable to set the temperature beyond the range defined during the previous SAVE-ENERGY setting. As
shown in Fig. 9, we have set the lower limit of cooling to 23 and the upper limit to 27 . After that, the ℃℃
user can only set the cooling temperature between 23~27 no matter from remote controller or wired ℃
controller.
If the upper limit temperature is equal to the lower limit, the system can only run at this temperature
setting under corresponding mode.
Release of SAVE-ENERGY Setting: After the setting of SAVE-ENERGY mode is effected, you may
simultaneously press “FAN”+“▼” buttons under turn-off state and hold them for 5 seconds to release the
SAVE-ENERGY function. But the value set before will not be cleared, and will be used as the initial
temperature for the next SAVE-ENERGY setting.
After a power failure, SAVE-ENERGY setting will be memorized and will remain active upon energization
next time.
Once set to SAVE-ENERGY mode, the SLEEP mode and AUTO mode will be shielded.
7.2.9 Display of Outdoor Environment Temperature (Fig. 7-10)
Normally, only the indoor environment temperature will be displayed in the TEMP. column. Pressing and
holding SLEEP button for 5 seconds under turn-on or turn-off mode, OUTDOOR ENVIRONMENT will
be displayed on the LCD. 10 seconds after displaying of the outdoor environment temperature, the
system jump back to the display of indoor environment temperature. Note: This function is unavailable
for the unit which is not equipped with Outdoor Ambient Sensor .
Fig. 7-11
Fig. 7-12 Fig. 7-13
31