Operating instructions

2. Lock the castors of the device. Press the lever downward to
lock them.
3. Attach the "Hot surface" warning sticker in a clearly visible
position for applications above
70 °C.
4.3
External consumer
4.3.1
Temperature control tubes and hose clamps
CAUTION!
Discharge of heat transfer liquid during operation
caused by use of unsuitable tubes
Scalding, frostbite
Use tubes with temperature resistance that is
appropriate for the operating temperature range of
the device.
Use tubes with a temperature resistance of at least
100 °C for the heater option.
CAUTION!
Contact with hot or cold tubes
Burns, frostbite
Use insulated tubes for temperatures below
0 °C or
above 70 °C.
The tubes specified below can be used for all heat
transfer liquids that are approved for the devices.
Tubes
Type
Device
Pump con-
nection
Required accesso-
ries
Maximum
operating
pressure
Clear
width x
outer
diameter
in mm
Tem-
perature
range in
°C
Cata-
logue
number
EPDM tube, insu-
lated
VC 600
M16 x 1 (10),
olive 13 mm
Olive HKO 026,
union nut HKM 032
< 1 bar 12 x 30 -35 ... 90 LZS 021
EPDM tube, not
insulated
VC 600
M16 x 1 (10),
olive 13 mm
Olive HKO 026,
union nut HKM 032
< 1 bar 9 x 11 10 ... 90 RKJ 111
Before commissioning
Variocool 25