Instruction Manual

39
4
6
5
6
3
3
3
3
3
FUSED DISCONNECT
(BY OTHERS)
(GRN.)
TRANSFORMER
O.L. RELAY
CONTACT
MOTOR STARTER
PUSHBUTTON
SEE NOTE #3
2.5 AMP FUSE
TYPICAL PILOT CONTROLS ONLY
COIL
(WHITE)
(BLACK)
(BLUE)
FOOT SWITCH
CONTACTOR
"UP" LIMIT
SWITCH
(WHEN USED)
AND FUSES TO BE MOUNTED IN NEMA 1 ENCLOSURE,
MOTOR STARTER, CONTROL TRANSFORMER, OVERLOADS,
PRE-WIRED, AND MOUNTED TO POWER UNIT.
1.
2.
OPTIONAL FOOTSWITCH W/ GUARD (NEMA 1) SHIPPED3.
LOOSE WHEN ORDERED. TO BE INSTALLED AND WIRED
TRANSFORMER PRIMARY CONNECTION DIAGRAMS ARE
LOCATED ON INSIDE OF FRONT COVER.
(XF)
230V.
(GRN)(GRN)
ORANGE - DOWN SOLENOID
GREEN - EQUIPMENT GROUND
STANDARD PUSHBUTTON
COLOR CODE
CONNECTION No. ON DEVICE.
ELECTRICAL LEAD (PIG TAIL)
BLACK - MOTOR
WHITE - MOTOR
RED - DOWN SOLENOID
IDENTIFICATIONS
ELECTRICAL SCHEMATIC
DN. SOL.
L1
L3
L3
L1
1 PHASE
230 VOLT
60 CYCLE
(BY OTHERS)
60 CYCLE
1 PHASE
230 VOLT
MOTOR:
3/4 HORSEPOWER
24V.
T2
BLACK
CONTACTS
CONTACTOR
T3
HEATERS
WHITE
O.L.
L1
L3
2
Figure 17: Electric Schematic; 230V / 1Ph / 24 V Control
GENERAL MAINTENANCE