Instruction Manual

38
FUSED DISCONNECT
(BY OTHERS)
(GRN.)
TRANSFORMER
O.L. RELAY
CONTACT
MOTOR STARTER
PUSH BUTTON
SEE NOTE #3
2.5 AMP FUSE
TYPICAL PILOT CONTROLS ONLY
COIL
(WHITE)
(BLACK)
(BLUE)
FOOT SWITCH
CONTACTOR
"UP" LIMIT
SWITCH
(WHEN USED)
AND FUSES TO BE MOUNTED IN NEMA 1 ENCLOSURE,
MOTOR STARTER, CONTROL TRANSFORMER, OVERLOADS,
PRE-WIRED, AND MOUNTED TO POWER UNIT.
1.
2.
OPTIONAL FOOT SWITCH W/ GUARD (NEMA 1) SHIPPED
3.
LOOSE WHEN ORDERED. TO BE INSTALLED AND WIRED
TRANSFORMER PRIMARY CONNECTION DIAGRAMS ARE
LOCATED ON INSIDE OF FRONT COVER.
(XF)
115V.
(GRN)(GRN)
ORANGE - DOWN SOLENOID
GREEN - EQUIPMENT GROUND
STANDARD PUSH BUTTON
COLOR CODE
CONNECTION No. ON DEVICE.
ELECTRICAL LEAD (PIG TAIL)
BLACK - MOTOR
WHITE - MOTOR
RED - DOWN SOLENOID
IDENTIFICATIONS
( ) INDICATES ACTUAL TERMINAL
ELECTRICAL SCHEMATIC
DN. SOL.
L1
L3
L3
L1
1 PHASE
115 VOLT
60 CYCLE
(BY OTHERS)
60 CYCLE
1 PHASE
115 VOLT
MOTOR:
3/4 HORSEPOWER
L1
L3
24V.
(ORANGE)
(RED)
(BLACK)
(WHITE)
T2
BLACK
CONTACTS
STARTER
T3
HEATERS
WHITE
O.L.
Figure 16: Electric Schematic; 115V / 1Ph / 24 V Control
GENERAL MAINTENANCE