Manual

30
CC
AS
MOTOR STARTER
CONTACTOR
COIL
O.L. RELAY
CONTACT
L1
L2
FUSED DISCONNECT
(BY OTHERS)
CONTACTS O.L.
MOTOR STARTER
L1
L2
T1
3
L1
L2
TRANSFORMER
(13) (14) 6 36
AUDIBLE SIGNAL
(WHEN USED)
3
3
3
3
(XF) (X1) (X2)
"UP" LIMIT SWITCH
(WHEN USED)
54
AUX.
CONTACT
AUX.
CONTACT
DN. SOL.
(BY AUTOQUIP)
7 ORG. BLU.
2
2
2
JUMPER
*BLK.
*
WHT.
*GRN.
*RED.
PUSHBUTTON
UP
DN
PRIMARY FUSE(S)
SECONDARY FUSE
NOTES:
1. "UP" LIMIT SWITCH ( OPTIONAL)
WHEN USED, REMOVE JUMPER BETWEEEN #4 AND #5.
2. "R" = RED FLASHING LIGHT (OPTIONAL).
3. "AS" = AUDIBLE SIGNAL (OPTIONAL).
4. SEE ASSEMBLY AND/OR SPEC. SHEET
FOR SPECIFIC VOLTAGES, OR CONTROLS
SUPPLIED AND CONFIGURATION.
5. PUSHBUTTON SHOWN AS TYPICAL
PILOT DEVICE.
6. TRANSFORMER PRIMARY CONNECTION
DIAGRAMS ARE LOCATED ON INSIDE
FRONT COVER OR ON DEVICE.
* COLOR CODE OF STANDARD
PENDENT PUSHBUTTON WHEN SUPPLIED.
( ) INDICATES ACTUAL TERMINAL
CONNECTION No. ON DEVICE
6
6
R
(A1) (A2) (95) (96)
(52) (51)
+
-
FLASHING RED LIGHT
(WHEN USED)
(GRN.)
(BLK.)
(WHT.)
FIELD WIRING TYP.
(BY OTHERS)
L2
L1
L3
T2
T3
Figure 11 Electrical Schematic; 230V/1PH (PLD-50)