Manual
21
DANGER!
HIGH VOLTAGE!! Disconnect and/or lock out the electrical supply to
the power unit prior to any maintenance being performed.
1. Change oil once a year or when it materially darkens or feels gritty. Also, check oil
for the presence of water (oil will turn milky in color.)
2. NEVER TRY TO DISASSEMBLE OR REPAIR A PUMP IN THE FIELD. These
pumps are high-precision devices requiring extreme precision in fit-up. When one is
damaged, there is seldom anything that can be repaired in the field. It is also more
economical to replace a pump than to refit old parts with new parts.
3. The pin, or roller bushing should be replaced whenever excessive wear is detected.
The rollers are furnished with the pressed-in bushing as a unit part.
DANGER!
To avoid personal injury, NEVER go under the lift platform until the load is
removed and the scissors mechanism is securely blocked in the open
position.
GENERAL MAINTENANCE