Instruction Manual

PROBLEM POSSIBLE CAUSE AND SOLUTION
Bridge raises slowly.
The structural members of the bridge may be
binding.
The tubing or hose is obstructed or broken. Where
pipe is used, check for obstruction in the line.
The hydraulic line or hose may be leaking.
The oil viscosity is not suited for the environmental
conditions. Refer to “Routine Maintenance” section
for oil recommendations.
Check the oil level in the reservoir.
The motor voltage/wiring may be incorrect.
The suction screen may be clogged. Remove and
clean the screen. Drain and replace the oil.
The suction line may be leaking air due to a loose
fitting. Tighten as needed.
The breather holes in the reservoir fill plug may be
clogged. Remove and clean.
The power unit pump may be defective.
Bridge lowers slowly.
The structural members of the bridge is binding.
The tubing or hose is obstructed or broken. Where
pipe is used, check for obstruction in the line.
The oil viscosity is not suited for the environmental
conditions. Refer to “Routine Maintenance” section
for oil recommendations.
The return filter may be clogged due to dirt or
damage.
TROUBLESHOOTING ANALYSIS
43