Instruction Manual
3" x 3" x 1/4" THK. x 24" LG.
PLACEMENT WHEN
(TYPICAL BOTH ENDS)
CURB ANGLES BY PIT CONTRACTOR.
HYDRAULIC POWER UNIT
MOUNTED ON 24" CUTOUT.
(2) 3/8" (SCH. 80) BLACK PIPE & FITTINGS FROM
REMOTE POWER UNIT
FOR POWER UNIT MOUNTED REMOTELY, INSTALL THE (3)
HYDRAULIC LINES & (1) CONTROL CONDUIT.
15 1/4"
24" CUTOUT
(1) 1/2" (SCH. 80) BLACK PIPE & FITTINGS FROM
REMOTE POWER UNIT TO CUTOUT FOR SAFETY LEGS.
REMOTE POWER UNIT TO CUTOUT FOR LIFTING RAMS.
____" CLEVIS CHANNEL
LENGTH AND DOCK
OPENING
____" HINGE CHANNEL
LENGTH
26"
12"
22"
18"
2" CLEARANCE
CONCRETE SUPPORT
IF CLEARANCE ALLOWS
6"H WHEEL CURBS
BRIDGE #1
___"
_____" (__' - __") DOCK FACE TO DOCK FACE
BRIDGE #2
STANDARD SPACING OF RAMS
WILL PERMIT INSTALLATION OF
POWER UNIT ON THE 24" MIN.
CUTOUT IF DESIRED.
FOR POWER UNIT MOUNTED UNDER BRIDGE ON THE CUTOUT, INSTALL ONLY
THE (2) CONDUITS. (2) 3/4" CONDUITS. (1) FOR CONTROL & (1) FOR POWER.
HYDRAULIC LINES & CONDUIT LINES TYPICAL BOTH BRIDGES.
PIT MOUNTED POWER UNIT
___"
OPTIONAL
AUTOMATIC
FOLDING LEGS
2" CLEARANCE
(TYP)
TYPICAL BOTH ENDS
26"
18"
22"
12"
NON - SKID
STEEL PLATE
INSTALLATION INSTRUCTIONS
Figure 11 Double Leaf Bascule Bridge – Plan View
19