Operating instructions
4
Central ventilation units KWL EC 700/1400/2000 D Pro / WW
Installation and operating instructions
1.11 Technical data
KWL EC 700 D Pro
Voltage/Frequency 230 V~/50 Hz Wiring diagram SS-1006
Rated current – ventilation 2,6 A Permissible air temperatures -20 °C bis 40 °C
Rated current – pre-heating 12,2 A Weight 110 kg
Max. total rated current 14,8 A Standby losses < 1 W
Pre-heating (outlet) 2,2 kW Design IP20
Post-heating (outlet) kW --
Electrical power feed to UV NYM-J
Capacities Vm
3
/h 510 - 330 - 210
KWL EC 700 D Pro WW
Voltage/Frequency 230 V~/50 Hz Wiring diagram SS-1006
Rated current – ventilation 2,6 A Permissible air temperatures -20 °C bis 40 °C
Rated current – pre-heating 12,2 A Weight 115 kg
Max. total rated current 14,8 A Standby losses < 1 W
Pre-heating (outlet) 2,2 kW Design IP20
Post-heating (outlet) kW 2,3 (bei 60/40 °C)
2,1 (bei 50/40 °C)
1,3 (bei 40/30 °C)
Electrical power feed to UV NYM-J
Capacities Vm
3
/h 510 - 330 - 210
KWL EC 1400 D Pro
Voltage/Frequency 3N~ 400 V/50 Hz Wiring diagram SS-1007
Rated current – ventilation 6,2/--/-- A Permissible air temperatures -20 °C bis 40 °C
Rated current – pre-heating --/6,5/6,5 A Weight 185 kg
Max. total rated current 6,2/6,5/6,5 A Standby losses < 1 W
Pre-heating (outlet) 4,5 kW Design IP20
Post-heating (outlet) kW --
Electrical power feed to UV NYM-J
Capacities Vm
3
/h 1000 - 650 - 400
KWL EC 1400 D Pro WW
Voltage/Frequency 3N~ 400 V/50 Hz Wiring diagram SS-1007
Rated current – ventilation 6,2/--/-- A Permissible air temperatures -20 °C bis 40 °C
Rated current – pre-heating --/6,5/6,5 A Weight 190 kg
Max. total rated current 6,2/6,5/6,5A Standby losses < 1 W
Pre-heating (outlet) 4,5 kW Design IP20
Post-heating (outlet) kW 4,7 (bei 60/40 °C)
4,2 (bei 50/40 °C)
2,7 (bei 40/30 °C)
Electrical power feed to UV NYM-J
Capacities Vm
3
/h 1000 - 650 - 400
KWL EC 2000 D Pro
Voltage/Frequency 3N~ 400 V/50 Hz Wiring diagram SS-1008
Rated current – ventilation 6,2/--/-- A Permissible air temperatures -20 °C bis 40 °C
Rated current – pre-heating 10,1/10,1/10,1 A Weight 265 kg
Max. total rated current 16,3/10,1/10,1 A Standby losses < 1 W
Pre-heating (outlet) 7,0 kW Design IP20
Post-heating (outlet) kW --
Electrical power feed to UV NYM-J
Capacities Vm
3
/h 1800 - 1150 - 720
KWL EC 2000 D Pro WW
Voltage/Frequency 3N~ 400 V/50 Hz Wiring diagram SS-1008
Rated current – ventilation 6,2/--/-- A Permissible air temperatures -20 °C bis 40 °C
Rated current – pre-heating 10,1/10,1/10,1 A Weight 270 kg
Max. total rated current 16,3/10,1/10,1 A Standby losses < 1 W
Pre-heating (outlet) 7,0 kW Design IP20
Post-heating (outlet) kW 8,1 (bei 60/40 °C)
7,3 (bei 50/40 °C)
4,6 (bei 40/30 °C)
Electrical power feed to UV NYM-J
Capacities Vm
3
/h 1800 - 1150 - 720
UK