Safety Information

Report No.: TB-EMC162281
Page: 7 of 25
TB-RF-075-1.0
1.7. Measurement Uncertainty
The reported uncertainty of measurement y ± Uwhere expended uncertainty U is
based on a standard uncertainty multiplied by a coverage factor of k=2providing a
level of confidence of approximately 95 %.
Test Parameters
Expanded
Uncertainty (U
Lab
)
Expanded
Uncertainty
(U
Cis
p
r
)
Conducted
Emission
Level Accuracy:
9kHz~150kHz
150kHz to 30MHz
±3.42 dB
±3.42 dB
±4.0 dB
±3.6 dB
Radiated Emission
Level Accuracy:
9kHz to 30 MHz
±4.60 dB N/A
Radiated Emission
Level Accuracy:
30MHz to 1000
MHz
±4.40 dB ±5.2 dB
Radiated Emission
Level Accuracy:
Above 1000MHz
±4.20 dB N/A
Mains Harmonic Voltage ±3.11% N/A
Voltage
Fluctuations &
Flicker
Voltage ±3.25% N/A
1.8. Test Facility
The testing report were performed by the Shenzhen Toby Technology Co., Ltd., in their
facilities located at 1A/F., Bldg.6, Yusheng Industrial Zone, The National Road No.107
Xixiang Section 467, Xixiang, Bao’an, Shenzhen, Guangdong, China. At the time of
testing, the following bodies accredited the Laboratory:
A2LA Certificate No.: 4750.01
The laboratory has been accredited by American Association for Laboratory
Accreditation (A2LA) to ISO/IEC 17025 2005 General Requirements for the
Competence of Testing and Calibration Laboratories for the technical competence in the
field of Electrical Testing. And the A2LA Certificate No.: 4750.01.
IC Registration No.: (11950A-1)
The Laboratory has been registered by Certification and Engineering Bureau of Industry
Canada for radio equipment testing. The site registration: Site# 11950A-1.