Safety Information

Report No.: TB-EMC162281
Page: 23 of 25
TB-RF-075-1.0
Attachment B--Electrostatic Discharge Test Data
Temperature :
22
Humidity : 50%
Power supply : DC 12V Test Mode : Mode 1
Required Performance Criteria: B
Air Discharge: ±2/±4/±8kV Contact Discharge: ±2/±4kV
Location Test Level (kV) No. of Discharge Judgment Result
A1
±2kV±4kV±8kV
20 A
PASS
A2 20 A
C1
±2kV±4kV
20 A
HCP
±4kV
40 A
VCP
±4kV
40 A