6. Radiated Electromagnetic Field Immunity Test
6.1. Test Requirements
6.1.1. Test Standard
EN 55024:2010+A1:2015 (EN 61000-4-3:2006+A1:2008+A2:2010)
6.1.2. Test Level
Level Field Strength V/m
1 1
2 3
3 10
X Special
Performance criterion: A
6.2. Test Setup
6.3. Test Procedure
The EUT are placed on a table, which is 0.8 meter high above the ground. The EUT is
set 3 meters away from the transmitting antenna, which is mounted on an antenna
tower. Both horizontal and vertical polarization of the antenna is set on test. Each of
the four sides of the EUT must be faced this transmitting antenna and measured
individually.
In order to judge the EUT performance, a camera is used to monitor its screen.
All the scanning conditions are as following: